2–32
STANDARDS AND ADJUSTMENTS
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
Q654-5
Cassette 5 size sensor (C5SZ4)
J308-B2
No. 219
1-d
Slide out the cassette while in
standby, and operate the detection
lever with a finger. (paper selection
for cassette 5)
Q653-5
Cassette 5 size sensor 3 (C5SZ3)
J308-B1
No. 219
1-c
Slide out the cassette while in
standby, and operate the detection
lever with a finger. (paper selection
for cassette 5)
When the lever
is operated
0
—
When the lever
is not operated
1
—
When the lever
is operated
0
—
When the lever
is not operated
1
—
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS7cu
Cassette 5 paper sensor (C5PD*)
J308A-9
No. 215
1-a
Slide out the cassette 5 while in
standby. (paper selection for
cassette 5)
PS6cu
Cassette 5 vertical path detection
(C5VPD)
J308B-9
No. 215
1-b
Slide out the cassette 5 while in
standby, and insert paper between
the pick-up guide plates.
When paper is
inserted
1
—
When paper is
not inserted
0
—
When the
cassette is slid
out
0
—
When paper is
put in the
cassette and the
cassette is slid in
1
—
Summary of Contents for NP6621
Page 4: ...ii ...
Page 8: ...vi ...
Page 48: ...3 2 IMAGE FAULTS ...
Page 49: ...3 3 IMAGE FAULTS NOT USED ...
Page 50: ...3 4 IMAGE FAULTS B Image Fault Samples not available ...
Page 80: ...4 16 TROUBLESHOOTING MALFUNCTIONS ...
Page 134: ...A 4 APPENDIX ...
Page 135: ...A 5 APPENDIX C GENERAL CIRCUIT DIAGRAM not available ...
Page 136: ...A 6 APPENDIX ...
Page 144: ...A 14 APPENDIX ...