transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Increase the transmission level of the
receiving machine.
##765 TX
After transmitting PPS-EOP in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##767 TX
After transmitting PPS-EOP in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##768 TX
After transmitting PPS-EOP in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##769 TX
After transmitting PPS-EOP in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##770 TX
After transmitting EOR-NULL in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##772 TX
After transmitting EOR-NULL in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##773 TX
After transmitting EOR-NULL in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##774 TX
After transmitting EOR-NULL in ECM
transmission, ERR has been received.
- Try a higher transmission level.
##775 TX
After transmitting EOR-MPS in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
##777 TX
After transmitting EOR-MPS in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##778 TX
After transmitting EOR-MPS in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
- Increase the period of time of the T5
time-over.
17 / 76
Summary of Contents for PIXMA MX882 Series
Page 32: ...8 Remove the main case no screws 28 76...
Page 35: ...4 Remove the LCD ass y no screws 31 76...
Page 55: ...2 Service Tool functions Service Tool screen Version 2 000 51 76...
Page 56: ...52 76...
Page 67: ...63 76...
Page 74: ...4 2 Integrated Inspection Pattern Print Print sample...
Page 75: ...4 3 Ink Absorber Counter Value Print Print sample 4 VERIFICATION AFTER REPAIR...
Page 78: ......