SW5
Spring
Compartment open/close arm
Compartment open solenoid(SL1)
Compartment open/close sensor(SR9)
Compartment open/close
detection switch(SW4)
Fan safety switch(SW5)
Air Assist Control
■ Overview
To facilitate separation of paper, the machine executes air assist control.
The fans (FM2, FM3) are combined to blow air against the paper so that the paper is shifted slightly to lose attraction, ultimately
preventing double-feeding.
To facilitate separation of paper in the high humidity environment, an air heater unit (H2) is equipped as standard.
A warming fan (FM2) with an air heater blows hot wind against paper to reduce the humidity, thus facilitating separation of paper.
2. Technology
20
Summary of Contents for POD Deck Lite-C1
Page 1: ...Revision 2 0 POD Deck Lite C1 Service Manual ...
Page 10: ...Product Overview 1 Features 5 Specifications 6 Names of Parts 7 Option Construction 10 ...
Page 17: ...Technology 2 Basic Configuration 12 Controls 15 Upgrading 26 ...
Page 33: ...Periodical Service 3 List of Work for Scheduled Servicing 28 ...
Page 37: ...6 Remove the base stay unit 3 Screws 3x 4 Disassembly Assembly 31 ...
Page 52: ... Procedure 1 Remove the Upper Cover 5 Screws 5x 4 Disassembly Assembly 46 ...
Page 69: ...5 Remove the Air Heater from rear of the Compartment 2 Screws 2x 4 Disassembly Assembly 63 ...
Page 72: ...2 Remove the Deck Pickup Release Solenoid 2 Screws 2x 4 Disassembly Assembly 66 ...
Page 93: ...Adjustment 5 Adjustment 88 Actions when Replacing the Parts 90 Other Adjustment 96 ...
Page 150: ...APPENDICES Service Tools 145 General Circuit Diagram 146 ...