background image

11 

9.

Troubleshooting 

This page lists problems frequently inquired of and their solutions. Before making 

inquiries, please check the corresponding items. 

If you still cannot solve your problem, please contact the customer support section 

mentioned at the end of this document. 

Status 

Check 

Result 

Next Check 

See 

A  or  B  phase 

digital  signals 

are not output. 

Is rotating 

speed 

in 

specifications 

range? 

Yes 

 

Check the power supply pin 
assignment and voltage.Check 
the output signal pin 
assignment and the receiver 
circuit. 

4-1 

4-2 

4-3 

4-4 

No 

 

Set rotating speed   

in    specifications range. 

7-3 

Signals   

are 

interrupted. 

Is rotating 

speed 

in 

specifications 

range? 

Yes 

 

Check for excessive load to the 

bearing 

 

Check  that  the  bandwidth  of 

your counter has not 

been exceeded. 

 

Check  for  noise  in  the  power 

supply and the frame ground. 

7-9 

7-3 

 

4-1 

 

No 

 

Set rotating speed   

in    specifications range. 

7-3 

phase 

Signals 

are 

not output. 

Is 

the 

reception 

machinery 

able  to  catch 

500ns 

pulse

 

Yes 

 

Check  the  Z  phase  signal  by   

oscilloscope 

7-3 

No 

 

Use  equipment  with  sufficient 

bandwidth.   

 

increase  pulse  the  width  using 

a  one-shot  multi-vibrator  (74 

LS221 etc.). 

4-3 

4-4 

5-1 

The 

actual 

position(angle) 

differs  greatly 

from  that  by 

the encoder 

Is 

the 

difference 

great? 

Yes 

 

Check  that  the  resolution 

setting is correct. 

4-5 

No 

 

Check for excessive load to the 

bearing 

 

Check 

that 

the 

 

shaft 

alignment is precise. 

7-9 

9.

9.

9.

9.

Troubleshooting

    

Summary of Contents for R-1SO

Page 1: ...purchasing Canon s product Before using the product be sure to read this manual particularly Safety Precautions Use the product as instructed in this manual to bring out the best from the product Keep this manual with care for future use whenever necessary English ...

Page 2: ...r or any other liquid splashes over it Do not install operate maintain or inspect the product with wet hands Do not disassemble or alter the product Caution Failure to take this precaution may result in physical injury or property damage Before installation operation maintenance or inspection check the device status well to confirm safety Be careful to static electricity Do not touch each pin of t...

Page 3: ...the product outside the range specified in this manual or alter it Do not disassemble the product or insert a tool through a gap Doing so may cause mechanical damage or damage the circuit by static electricity 1 2 Installation Place Mount the product in an ambient temperature range from 0 to 50 C avoiding direct sunlight and a heat source Use the product away from a noise source such as high volta...

Page 4: ... per rotation The pulses of incremental signal of inter edge spacing is 324 000 pulse per rotation at its maximum and resolution of angle is set at 4 0 seconds The signal of this product is open collector output therefore easy to connect with your equipment 3 Dimension and Section Names 2 2 2 2 Outline Outline Outline Outline 3 3 3 3 Dimension and Section Names Cable length 300 mm Encoder main bod...

Page 5: ...nd in the stable electric potential Be sure to avoid pulse like noise current in this line as it may lead to deterioration of the semiconductor laser light source and cause errors from noise contamination of the signal 4 2 Power Supply Use power supply satisfying the following specifications Voltage Current capacity DC 5 0 25 V 200mA no load DC 5 0 25 V 100mA Pin No Function Pin No Function 1 A ph...

Page 6: ...ircuit 4 4 1 Encoder signal 4 4 2 LD Alarm signal LD monitor LD Alarm LD alarm output to 74LS14 etc A B phase digital A B phase digital out Z phase digital out Comparator 319 or equivalent Z phase digital 74LC03 A B phase to 74LS14 etc Z phase 680Ω to 74LS14 etc 390Ω 5V TC75S56F Comparator ...

Page 7: ...hase signal The pulse width of the Z phase is 500 1250 nsec In case the receiving IC needs a wider pulse width increase the width using a one shot multi vibrator 74 LS221 etc 5 2 LD alarm signal output LD driving current is always monitored and goes Low level when the LD current exceed 1 5 times at the time of the shipment 5 5 5 5 Output wave form A phase B phase Z phase A phase B phase 500 1250ns...

Page 8: ...the thrust fluctuation should be 1 µm or less When precise shaft alignment is impossible it is recommended to absorb the shaft misalignment shaft deflection or thrust fluctuation by using a flexible coupling A flexible coupling with enough torsional rigidity should be selected to obtain precise transmission When attaching the flexible coupling to the encoder shaft be very careful not to apply any ...

Page 9: ...ave incremental signal output A B phase difference 90 10 Z phase Rectangle wave signal output Z phase pulse width 500 1250 nsec LD Alarm TTL level 7 6 Starting Torque 0 0882 Ncm or less 9 gfcm or less 7 7 Rotor inertial moment 8 gcm2 GD2 7 8 Permissible rotating speed 5 000 rpm 7 9 Permissible load Radial 3 92 N 0 4 kgf Thrust 9 8 N 1 0 kgf 7 10 Vibration and Shock Resistance Vibration 10G 500Hz S...

Page 10: ...ting Dimensions 7 14 Standards Complying With RoHS CE Marking VCCI 2010 FCC Part 15 2008 8 About Disposal When disposing of this product follow the rules of proposal specified by the country or local government 8 8 8 8 About Disposal ...

Page 11: ...rrupted Is rotating speed in specifications range Yes Check for excessive load to the bearing Check that the bandwidth of your counter has not been exceeded Check for noise in the power supply and the frame ground 6 7 9 7 3 4 1 No Set rotating speed in specifications range 7 3 Z phase Signals are not output Is the reception machinery able to catch 500ns pulse Yes Check the Z phase signal by oscill...

Page 12: ...or abnormal voltage 5 Fault or damage of this product attributable to the use of a part not made by Canon 6 Fault attributable to inappropriate storage e g storage in a place of high temperature and humidity or with naphthalene or camphor or inappropriate maintenance 7 Product serial number labeled on the product unknown 8 Fault attributable to other equipment connected 3 Canon will take no respon...

Page 13: ...G KOREA INC Canon BS Tower 9F 168 12 Samseong Dong Gangnam Gu Seoul 135 090 Korea Phone 82 2 6445 0056 CANON CANON CANON CANON SEMICONDU SEMICONDU SEMICONDU SEMICONDUCTOR EQUIPMENT TAIWAN INC CTOR EQUIPMENT TAIWAN INC CTOR EQUIPMENT TAIWAN INC CTOR EQUIPMENT TAIWAN INC 8F No 101 Sung Ren Road Taipei 110 Taiwan Phone 822 2 8789 2100 Fax 822 2 8789 2586 CANON MARKETING JAPAN INC CANON MARKETING JAPA...

Reviews: