3
(3) Turn on the power to the main unit.
After connecting TOP COVER ASS’Y and the main unit only with the flexible cable, press the
power ON/OFF button to turn on the power to the main unit.
MAIN PCB ASS’Y
TOP COVER ASS’Y
Test point
M7
M1
M10
M8
VR
Flexible cable
Power ON/OFF button
(4) Attach the screws and the connector removed in step (1), and then remove the TOP COVER SECTION.
Connect the SELPHY CP770 and the digital camera with the interface cable to make direct printing pos-
sible.
(5) While Printing an arbitrary image from the digital camera, measure the voltage of the test points (
,
)
during printing, and adjust the volume (VR) so that the voltage value is within
±
0.03 V of the voltage value
calculated in step (2).
Test point
M7
M1
M10
M8
VR
MAIN PCB ASS’Y
(6) After the voltage is adjusted, wait for five minutes.
(7) Print the standard image (
2
).
Note:
Use only the copy that was printed first.
If it fails to print, wait for five minutes and print the standard image again.