COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
3-1
CHAPTER 3 INSTALLATION
1 Selecting the Site
The site must meet the following requirements; if possible, visit the user’s before the ma-
chine is delivered:
1. The site must offer a power outlet whose rating is as indicated 230 volts (±10%) and
which may be used exclusively for the machine.
2. The site temperature must be between 0° and 35°C (32° and 95°F) and between 35%
and 85% humidity. Avoid an area near a water faucet, water boiler, humidifier, and re-
frigerator.
3. The site must not be near a source of fire, or must not be subject to dust or ammonium
gas. Also, avoid areas exposed to direct rays of the sun; if necessary, provide curtains.
4. The level of ozone generated by the machine while in use will not affect the health of
the human body. However, some individuals may find its odor unpleasant. Be sure to
ventilate the room well to provide a good working environment.
5. The machine will have to be at least 10cm/3.9" from any wall, offering enough space for
its use.
50cm
50cm
50cm
10cm
F03-101-01
6. The machine will have to be placed in a well-ventilated area of the room. Do not, how-
ever, place it near the inlet of air.