COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
CHAPTER 5 MECHANICAL SYSTEM
5-20
2.2.3 Removing the Sensor PCB
1) Remove the ADF (copyboard cover).
(ADF; See 2.8.1.1)
2) Remove the copyboard glass. (See
2.1.3)
3) Move the contact sensor to the center.
4) Remove the 2 screws [1], and detach the
left upper cover [2].
[2]
[1]
F05-202-07
5) Remove the sensor flag [3] and the
spring [4].
6) Disconnect the connector [5].
7) Remove the 2 screws [6], and detach the
sensor PCB [7].
[7]
[5]
[4]
[3]
[6]
F05-202-08