COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
CHAPTER 5 MECHANICAL SYSTEM
5-40
1) Remove the right cover. (See 2.1.1.2)
2) Free the 2 hooks [1], and slide the 2
manual feed pickup roller retainers [2]
to the left and right.
[2]
[1]
[1]
F05-206-11
3) Free the hook [3], and slide the manual
feed pickup roller [4] to the right to de-
tach.
[4]
[3]
F05-206-12
2.6.5 Removing the Manual Feed Pickup Roller