CHAPTER 2 USING THE MACHINE
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
2-46
3.6 Numeric Parameter Setting (#3 NUMERIC Param.)
No.
02
03
04
05
06
09
10
11
13
15
16
17
18
19
20
21
22
24
25
27
28
Item
RTN transmission condition (1)
RTN transmission condition (2)
RTN transmission condition (3)
NCC pause length (pre-ID code)
NCC pause length (post-ID code)
number of digits of telephone numbers in
comparison between transmitting and receiv-
ing machine
line connection identification time length
T.30 T1 timer (for reception)
T30.EOL timer
hooking detection time length
time to tentative response at time of fax/tel
switch-over
pseudo RBT signal pattern ON length
pseudo RBT signal pattern OFF time length
(short)
pseudo RBT signal pattern OFF time length
(long)
pseudo CI signal pattern ON time length
pseudo CI signal pattern OFF time length
(short)
pseudo CI signal pattern OFF time length
(long)
fax/tel switch-over pseudo RBT transmission
level
answer telephone CNG motor time length
V.21 low-speed flag preamble detection time
length
menu selection screen display time length
Range of settings
1 to 99%
2 to 99 times
1 to 99 lines
0 to 60 sec
0 to 60 sec
0 to 20 digits
0 to 9999 (10ms)
0 to 9999 (10ms)
500 to 3000 (10ms)
0 to 999 (10ms)
0 to 9 sec
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 20 dBm
0 to 999 sec
1 to 99 (10ms)
1 to 60 sec
Initial setting
10
15
12
4
4
6
5500
3500
1300
120
4
100
0
200
100
0
200
20
60
3
3