Parts Replacement and Cleaning Procedure > Major Units > Removing the Process Tray Lower Unit > Procedure
Parts Replacement and Cleaning Procedure > Major Units > Removing the Process Tray Lower Unit > Procedure
Removing the Process Tray Lower Unit
■
Preparation
1) Remove the Finisher Unit from the connected equipment(Refer to page 4-9).
2) Remove the Staple Cartridge(Refer to page 4-22).
3) Remove the Front Cover(Refer to page 4-15).
4) Remove the Rear Cover(Refer to page 4-16).
5) Remove the Upper Cover(Refer to page 4-17).
6) Remove the Paddle Motor (M3) (Refer to page 4-44).
7) Remove the Staple Unit(Refer to page 4-23).
8) Remove the Front Door Switch (S15) (Refer to page 4-53).
9) Remove the Finisher Lower Feed Guide Unit(Refer to page 4-27).
10) Remove the Process Tray Upper Unit (Front) by referring to "Removing the Process Tray
Upper Unit (Front/Rear)" (Refer to page 4-35).
11) Remove the Grate-shaped Guide(Refer to page 4-20).
12) Remove the Finisher Controller PCB(Refer to page 4-55).
F-4-102
■
Procedure
1) Remove the Process Tray Lower Unit [1].
• 4 Connectors [2]
• 2 Wire Saddles [3]
• 2 Screws [4]
• 2 Hooks [5]
2x
2x
3x
1x
[2]
[2]
[2]
[3]
[4]
[5]
[1]
F-4-103
Summary of Contents for Staple Finisher-S1
Page 6: ...Safety Precautions Notes Before Servicing Points to Note at Cleaning ...
Page 8: ...1 1 Product Outline Product Outline Features Specifications Names of Parts ...
Page 36: ...3 3 Periodic Servicing Periodic Servicing List of Work for Scheduled Servicing ...
Page 94: ...5 5 Adjustment Adjustment Adjustment Item Dip Switch Function ...
Page 113: ...Appendix Service Tools General Circuit Diagram ...