4
4
4-41
4-41
Parts Replacement and Cleaning Procedure > Major Units > Separating the Buffer Upper Feed Guide Unit from the Buffer Lower Feed Guide Unit > Procedure
Parts Replacement and Cleaning Procedure > Major Units > Separating the Buffer Upper Feed Guide Unit from the Buffer Lower Feed Guide Unit > Procedure
Separating the Buffer Upper Feed Guide Unit from the
Buffer Lower Feed Guide Unit
■
Preparation
1) Remove the Finisher Unit from the connected equipment(Refer to page 4-9).
■
Procedure
CAUTION:
When separating the Buffer Upper Feed Guide Unit [1] from the Buffer Lower Feed
Guide Unit [2], the Open/Close Spring [3] might bounce out so be careful not to lose it
when disassembling/assembling the unit.
[1]
[2]
[3]
F-4-105
F-4-104
1) Release the Release Handle [1] and open the Buffer Upper Feed Guide Unit [2].
[1]
[2]
2) Remove the E-ring [1] and remove the Buffer Upper Feed Guide Unit [3] while releasing the
tension of the Open/Close Spring [2].
• 2 Shafts [4]
[1]
[2]
[3]
[4]
F-4-106
F-4-107
Summary of Contents for Staple Finisher-S1
Page 6: ...Safety Precautions Notes Before Servicing Points to Note at Cleaning ...
Page 8: ...1 1 Product Outline Product Outline Features Specifications Names of Parts ...
Page 36: ...3 3 Periodic Servicing Periodic Servicing List of Work for Scheduled Servicing ...
Page 94: ...5 5 Adjustment Adjustment Adjustment Item Dip Switch Function ...