5
5
Service Mode
Service Mode
5-9
5-9
Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW12
Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW12
■
SSSW-SW12
●
Functional Construction
Bit
Function
1
0
0 Time-out period for one page upon transmission
1
0
1 Time-out period for one page upon transmission
1
0
2 Time-out period for one page upon (HT transmission)
1
0
3 Time-out period for one page upon (HT transmission)
1
0
4 Time-out period for one page upon reception
1
0
5 Time-out period for one page upon reception
1
0
6 not used
-
-
7 Respective page timer settings for transmission and for reception
enable
do not enable
The machine will stop the ongoing communication if the transmission/reception of a single
original page takes 32 min or more. To use the timer for a purpose other than this function,
refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all
modes will depend on the setting of bit 0 and bit 1.
T-5-7
Time-Out Length for Transmission/Reception
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
8 min
0
*
*
*
*
*
0
0
16 min 0
*
*
*
*
*
0
1
32 min 0
*
*
*
*
*
1
0
64 min 0
*
*
*
*
*
1
1
Time-Out Length for Transmission (in text mode)
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
8 min
1
*
*
*
*
*
0
0
16 min 1
*
*
*
*
*
0
1
32 min 1
*
*
*
*
*
1
0
64 min 1
*
*
*
*
*
1
1
Time-Out Length for Transmission (image mode other than text mode)
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
8 min
1
*
*
*
0
0
*
*
16 min 1
*
*
*
0
1
*
*
32 min 1
*
*
*
1
0
*
*
64 min 1
*
*
*
1
1
*
*
Time-Out Length for Reception
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
8 min
1
*
0
0
*
*
*
*
16 min 1
*
0
1
*
*
*
*
32 min 1
*
1
0
*
*
*
*
64 min 1
*
1
1
*
*
*
*
T-5-8
T-5-9
T-5-10
T-5-11