5
5
Service Mode
Service Mode
5-11
5-11
Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW26
Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW26
■
SSSW-SW25
●
Functional Construction
Bit
Function
1
0
0 transmission telephone number indicated report other party's
caller's
1 not used
-
-
2 not used
-
-
3 not used
-
-
4 not used
-
-
5 not used
-
-
6 not used
-
-
7 not used
-
-
Detailed Discussions of Bit 0
Use it to select the transmission telephone number indicated on the report at the end of
transmission.
caller's number: indicates the telephone number of the caller on the report.
number of other party: indicates the telephone number (CSI signal data) sent from the other
part on the report.
T-5-14
■
SSSW-SW26
●
Functional Construction
Bit
Function
1
0
0 not used
-
-
1 not used
-
-
2 confirmation screen for broadcasting
display
do not display
3 not used
-
-
4 not used
-
-
5 not used
-
-
6 not used
-
-
7 error report at time of transmission
suspension
do not generate
generate
Detailed Discussions of Bit 2
Use it to enable/disable indication of a confirmation message before broadcasting in
consideration of a mistake during input of addresses.
Detailed Discussions of Bit 7
Use it to enable/disable generation of an error report in response to a press on the Stop key
to suspend transmission.
T-5-15
Summary of Contents for Super G3 FAX Board-AP1
Page 1: ...6 5 4 3 2 1 Super G3 FAX Board AP1 Service Manual Rev 1 ...
Page 6: ...1 1 Product Outline Product Outline Product Outline Specifications ...
Page 8: ...2 2 Technology Technology Technology Basic Construction Controls ...
Page 15: ...4 4 Error Code Error Code Error Code Overview User Error Code Service Error Code ...