background image

Commands

RCCH

Mode

Control Setting

Reference

Function

Remote control setting

Parameter

ID

Parameter Meaning

1

Remote control channel 1

2

Remote control channel 2

The RANGE command can be used to obtain the parameter range that can be set at that time.

Response

An 'i:OK' is returned after setting is successful.

Description

This sets the remote control channel used at the projector side to 1 or 2.

(1) This command is identical to the Remote control function in the System settings menu.
(2) The GET command can be used to retrieve the current terminal setting.

Example

Setting

> RCCH=1

This sets the remote control channel to ch1.

< i:OK

Reference

>

GET RCCH or ?RCCH

This retrieves the remote control setting state.

<

g:RCCH=2

Obtain settable parameters

> RANGE RCCH
< r:RCCH=I,1,2

Commands are indicated by “>”, and responses are indicated by “<”

Supported Command States

Power supply

Input

Mode

OFF

ON

PM

D-RGB

A-RGB1 A-RGB2

Comp

Video

S-Video

None

Remote

Local

×

×

×

If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.

When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.

Summary of Contents for SX50 - REALiS SXGA+ LCOS Projector

Page 1: ...tion Flow Error List Command List Command System Chart Power Management Mode Key Spaces of or more characters Tab 09h other separators Spaces of 1 or more characters Tab 09h other separators Separator...

Page 2: ...ent Mode 8 Command List 9 Command Descriptions REMOTE LOCAL POWER INPUT AUTOPC DOTS TRACK HPOS VPOS HPIX VPIX SEL ASPECT IMAGE BRI CONT SHARP GAMMA DGAMMA PROG WB WBRGB SAT HUE ACADJUST 6AXR LAMP RESE...

Page 3: ...ntrolled from the PC The following symbols are used in these specifications Symbol Description Space with 0 or more characters 20h Tab 09h or other separator Space with 1 or more characters 20h Tab 09...

Page 4: ...aracters are not distinguished All are considered single byte characters Communication procedure No procedure Flow control None Error control None Break signal Not supported Time out Tc Character inte...

Page 5: ...o be returned in some cases BUSY WARN ERR Control command character string Control name Parameter value GET RANGE Setting Setting command Character string Command that sets values for each parameter T...

Page 6: ...on Example IMAGE 2 w USER_COMMAND_VERSION_IS_UPDATED ERR ERR response An error message is output Error response character string e Error code Error message Error code is expressed as a four digit hexa...

Page 7: ...Cable The connection diagram for the cable connecting the PC and projector is shown below...

Page 8: ...ata already received is lost and the mode is reset to receive standby again Command One response is always returned for each command sent from the PC Response However note that a response may not be r...

Page 9: ...namic gamma DGAMMA Progressive PROG This is set for each input signal and image quality Screen color correction WB RGB adjustment WBRGB Color saturation setting SAT Hue setting HUE Advanced color corr...

Page 10: ...uter startup REMOTE command Manual power on off LOCAL command Operation buttons Main unit keys All available Only POWER button is available Remote control keys All available Only POWER button is avail...

Page 11: ...tion function operate in each control mode Key Emulation LOCAL mode REMOTE mode Unlock Remote control lock Main unit key lock Unlock Remote control lock Main unit key lock Remote control POWER only PO...

Page 12: ...SX50 settings If the SX50 is set to REMOTE mode during standby it changes to the projection state Remote mode Projecting in progress 70 seconds elapsed POWER OFF Lamp cooling in progress Commands Pow...

Page 13: ...ection RGB adjustment 23 SAT Color level setting 24 HUE Color balance setting 25 ACADJUST Advanced color adjustment 26 6AXR 6 axis color adjust R setting 27 6AXG G setting 28 6AXB B setting 29 6AXC C...

Page 14: ...esponse Description This includes the command function conditions and notes Example This provides command usage examples Supported command states This defines the environments that support the command...

Page 15: ...ent input source Change the input source The current input source is indicated in parentheses 13 2010 e NO_SIGNAL There is no signal input Input the signal 201X e INVALID_SIGNAL This cannot be execute...

Page 16: ...e control emulation function RC command in Local mode for the following functions Function RC command parameter No display NOSHOW Freeze screen FREEZE Digital zoom DZOOM_P DZOOM_M Presentation timer P...

Page 17: ...0 0 CONT Sharpness 0 0 0 0 SHARP Gamma 0 0 0 0 GAMMA Dynamic gamma 0 0 0 0 DGAMMA Screen color correction NORMAL NORMAL NORMAL NORMAL WB Screen color correction va 0 0 0 0 0 0 0 0 0 0 0 0 WBRGB Advanc...

Page 18: ...lamp on state is activated unconditionally 4 Except for RC and MAIN the control commands can be used in Remote mode only RC and MAIN can be used in Local mode only The following projector modes and se...

Page 19: ...commands can be used during Local mode REMOTE LOCAL RC MAIN GET MODE 2 This command can be used in any projector state 3 The current mode can be viewed with the GET command Example Mode switching LOC...

Page 20: ...that it is in the controlled state off or on 3 The table below shows the POWER command responses according to the power supply state POWER Command Responses by Power Supply State Command POWER ON POW...

Page 21: ...INAL command A RGB2 and COMP cannot be selected e 1001 TERMINAL_OUT is returned 3 The Get command can be used to retrieve the current input Example Setting INPUT VIDEO VIDEO input select i OK Referenc...

Page 22: ...f horizontal vertical display dots 3 To confirm modified setting values use the GET command of the respective parameter Example AUTOPC i OK Commands are indicated by and responses are indicated by Sup...

Page 23: ...he current total number of dots Example Setting DOTS 1650 The total number of dots is 1650 i OK Reference GET DOTS or DOTS This retrieves the total number of dots g DOTS 1200 Obtain settable parameter...

Page 24: ...ent tracking adjustment value Example Setting TRACK 25 The tracking adjustment value is set to 25 i OK Reference GET TRACK or TRACK This retrieves the tracking adjustment setting value g TRACK 21 Obta...

Page 25: ...e GET command can be used to retrieve the current horizontal and vertical position Example Setting HPOS 12 This sets the horizontal value to 12 i OK Reference GET VPOS or VPOS g VPOS 8 Obtain settable...

Page 26: ...used to retrieve the current horizontal and vertical position Example Setting HPIX 1024 This sets the horizontal resolution to 1024 i OK Reference GET VPIX or VPIX This retrieves the vertical resoluti...

Page 27: ...1035i 720p 575p 480p 575i Includes 288p PAL non interlaced signal 480i Includes 240p NTSC non interlaced signal UNKNOWN No color 1080p and other signals Example Setting SEL AUTO This sets the input s...

Page 28: ...ings menu 3 The GET command can be used to retrieve the current screen display mode Example Setting ASPECT WIDE This sets the screen size to WIDE i OK Reference GET ASPECT or ASPECT This retrieves the...

Page 29: ...s Brightness Contrast Sharpness Gamma correction Dynamic gamma Progressive Screen color correction RGB adjustment value Color level Color balance Advanced color correction 6 axis correction 4 The GET...

Page 30: ...l and image mode 3 The GET command can be used to retrieve the current brightness Example Setting BRI 10 This sets the brightness to 10 i OK Reference GET BRI or BRI This retrieves the brightness g BR...

Page 31: ...and image mode 3 The GET command can be used to retrieve the current contrast Example Setting CONT 3 This sets the contrast to 3 i OK Reference GET CONT or CONT This retrieves the contrast g CONT 3 O...

Page 32: ...nd image mode 3 The GET command can be used to retrieve the current sharpness Example Setting SHARP 3 This sets the sharpness to 3 i OK Reference GET SHARP or SHARP This retrieves the sharpness g SHAR...

Page 33: ...ode 3 The GET command can be used to retrieve the current gamma correction Example Setting GAMMA 1 This sets the gamma correction to 1 i OK Reference GET GAMMA or GAMMA This retrieves the gamma correc...

Page 34: ...ode 3 The GET command can be used to retrieve the current dynamic gamma function state Example Setting DGAMMA 1 This turns on the dynamic gamma function i OK Reference GET DGAMMA or DGAMMA This retrie...

Page 35: ...conversion 1080i 720p 480p 1035i 575p 4 The GET command can be used to obtain the current progressive conversion process state 1 Conversion process in progress 0 No conversion Example Setting PROG 0...

Page 36: ...set using the WBRGB command 3 This sets the currently selected input and image mode 4 The GET command can be used to retrieve the current screen color correction Example Control WB NORMAL This sets t...

Page 37: ...ection in the Image adj menu 3 With this command the R G and B values can be set in a single operation 4 This sets the currently selected input signal and image mode 5 The GET command can be used to r...

Page 38: ...ieve the current color saturation Example Setting SAT 10 This sets the color saturation to 10 i OK Reference GET SAT or SAT This retrieves the color saturation g SAT 1 Obtain settable parameter range...

Page 39: ...de 4 The GET command can be used to retrieve the current hue Example Setting HUE 8 This sets the hue to 8 i OK Reference GET HUE or HUE This retrieves the hue g HUE 1 Obtain settable parameter range M...

Page 40: ...xis correction R to Y color balance and color level settings commands 6AXR to 6AXY to set the hue and color saturation for each axis 3 This sets the currently selected input signal and image mode 4 Th...

Page 41: ...tical to the 6 axis color adjust function under Advanced color adjustment in the Image adj menu 3 This sets the currently selected input signal and image mode 4 The GET command can be used to retrieve...

Page 42: ...in the Image adj menu 2 The GET command can be used to retrieve the current light output Example Setting LAMP NORMAL The lamp output is set to Normal i OK Reference GET LAMP or LAMP This retrieves th...

Page 43: ...justment items are initialized and then the adjustment values are optimized for the signal Reset of system settings 1 The following items are initialized Image Adjustment items Full Image mode Executi...

Page 44: ...range of the vertical keystone value 4 Use the RANGE command to obtain the range of settable values immediately before setting the vertical value and horizontal value 5 The GET command can be used to...

Page 45: ...e volume setting can be made when set to Mute no sound will be made 4 The GET command can be used to retrieve the current volume Example Setting AVOL 18 This sets the volume to 18 i OK Reference GET A...

Page 46: ...g the MUTE button on the remote control 3 Mute control enables simultaneous control of the audio and beep sound 4 The GET command can be used to obtain the currentMute setting Example Setting MUTE ON...

Page 47: ...beep sound is made even if the beep volume is set 3 The GET command can be used to retrieve the current BEEP sound output Example Setting BEEP 0 This mutes the BEEP sound i OK Reference GET BVOL or B...

Page 48: ...ed the keystone settings return to their initial values HKS 0 VKS 0 3 The GET command can be used to retrieve the current flip display state Example Setting IMAGEFLIP REAR This displays the image back...

Page 49: ...mode is set to Exit mode or Standby mode It is enabled in Local mode only 3 The GET command can be used to retrieve the current Power Management mode Example Setting PMM STANDBY This sets the Power Ma...

Page 50: ...mage needs to be registered beforehand Otherwise a e 1002 NO_LOGO_CAPTURED is returned 3 The GET command can be used to obtain the current screen displayed at startup Example Setting PJON CANON This s...

Page 51: ...image needs to be registered beforehand Otherwise a e 1002 NO_LOGO_CAPTURED is returned 3 The GET command can be used to obtain the current display screen at no signal Example Setting NOSIG BLUE This...

Page 52: ...age needs to be registered beforehand Otherwise a e 1002 NO_LOGO_CAPTURED is returned 3 The GET command can be used to obtain the current display screen when nothing is shown Example Setting NOSHOW LO...

Page 53: ...registered beforehand The error e 1002 NO_LOGO_CAPTURED is returned 3 The GET command can be used to retrieve the current display position Example Setting LOGOPOS UPPER_R This sets the logo display po...

Page 54: ...the Language function in the System settings menu 2 The GET command can be used to retrieve the current language Example Setting LANG SWE This sets the display language to Swedish i OK Reference GET...

Page 55: ...en the A RGB2 or COMP input is selected 3 The GET command can be used to retrieve the current terminal setting Example Setting TERMINAL IN This sets to input i OK Reference GET TERMINAL or TERMINAL Th...

Page 56: ...ion remote control or main unit commands even if the main unit or remote control keys are locked 3 The GET command can be used to retrieve the current key lock settings Example Setting KEYLOCK RC This...

Page 57: ...e System settings menu 2 The GET command can be used to retrieve the current terminal setting Example Setting RCCH 1 This sets the remote control channel to ch1 i OK Reference GET RCCH or RCCH This re...

Page 58: ...e button pressing request is received correctly It does not indicate if the operation for the pressed button was executed properly Description This emulates pressing of the remote control buttons for...

Page 59: ...est is received correctly It does not indicate if the operation for the pressed button was executed properly Description This emulates the pressing of the front panel buttons for controlling the proje...

Page 60: ...URATION SETTING VALUE HUE HUE SETTING VALUE ACADJUST ADVANCED COLOR CORRECTION METHOD 6AXR 6 AXIS CORRECTION R SETTING VALUE 6AXG G SETTING VALUE 6AXB B SETTING VALUE 6AXC C SETTING VALUE 6AXM M SETTI...

Page 61: ...PRESENTATION CINEMA SRGB BRI BRI BRIGHTNESS NUMBER CONT CONT CONTRAST SETTING VALUE NUMBER SHARP SHARP SHARPNESS SETTING VALUE NUMBER GAMMA GAMMA GAMMA SETTING VALUE NUMBER DGAMMA DGAMMA 1 0 PROG PROG...

Page 62: ...ID Meaning NO_ERROR No error ABNORMAL_TEMPERATUR Temperature error FAULTY_LAMP Lamp error FAULTY_LAMP_COVER Lamp cover error FAULTY_COOLING_FAN Cooling fan error FAULTY_POWER_SUPPLY Power supply erro...

Page 63: ...UST 6AXR Y VKS HKS AVOL MUTE BVOL IMAGEFLIP PMM PJON NOSIG NOSHOW LOGOPOS LANG LAMP TERMINAL KEYLOCK RCCH SIGNALSTATUS LAMPCOUNTER ERR PRODCODE ROMVER COMVER If a state is not supported INVALID_MODE N...

Page 64: ...correction method WBRGB Screen color correction value RGB SAT Color saturation setting value HUE Hue setting value ACADJUST Advanced color correction method 6AXR 6 axis correction R setting value 6AXG...

Page 65: ...Setting 2 minimum value Setting 2 maximum value Setting N minimum value Setting N maximum value Description This retrieves the setting range of each parameter 1 The parameter setting range can change...

Page 66: ...G WB WBRGB SAT HUE ACADJUST 6AXR Y VKS HKS AVOL MUTE BVOL IMAGEFLIP PMM PJON NOSIG NOSHOW LOGOPOS LANG LAMP TERMINAL KEYLOCK RCCH If a state is not supported INVALID_MODE NOT_POWER_SUPPLIED or INVALID...

Reviews: