1-28
Setting the Image Server, Audio Server and HTTP
Server (Server)
Image Server
(1) [Maximum Number of Clients]
Set the maximum number of clients that can be connected to the camera at the same time.
Up to 30 clients can be set. If 0 is set, connection is prohibited except for Admin Viewer.
(2) [Camera Control Queue Length]
Set the maximum queue length of requests for the camera control privilege from clients. The
maximum number is 30. Enter an integer from 0 to 30. If 0 is set, camera control is prohibited
except by the Administrator.
(3) [Maximum Connection Time (sec.)]
Set the time in seconds during which an individual client can connect to the camera. The
maximum time is 65535 seconds. Enter an integer from 0 to 65535.
If 0 is entered, the connection time becomes unlimited.
(4) [Camera Control Time (sec.)]
Set the maximum time during which the viewer can control the camera. The maximum time is
3,600 seconds. Enter an integer from 1 to 3600.
You can set the following items.
z
Image Server
Set the items needed to deliver image from the camera.
z
Audio Server
Set the items relating to transmitting/receiving audio.
z
HTTP Server
Set the HTTP port and web page delivery.