4. MECHANICAL SYSTEM
4-102
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
B. Upper Fixing Cleaner
Assembly
1. Removing the Upper Fixing Web
1)
Open the front cover (left), shift down the
fixing assembly lever, and slide out the fixing
unit.
2)
Remove the fixing assembly knob (1 screw),
and remove the fixing assembly lever (2
screws).
3)
Remove the two screws, and remove the
fixing assembly front cover.
4)
Open the external delivery unit and the
internal delivery unit.
5)
Remove the screw [1], and remove the fixing
assembly upper cover [2].
Figure 4-1001B
6)
Remove the two screws [3], and remove the
upper fixing web unit [4].
Figure 4-1002B
7)
Insert the process unit tool [5] into the return-
stop plate [6] as shown in Figure 4-1003B, and
release the web [7].
Figure 4-1003B
[1]
[2]
[3]
[3]
[4]
[5]
[6]
[7]