COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
5-9
5. INSTALLATION
Step
10
11
12
Work
Remove the four primary charging
assemblies.
Remove the four photosensitive drum
positioning knobs.
The knobs have a two-layer
construction. To remove, turn the small
knob at the center counterclockwise.
Remove the two screws from the
process unit.
Remarks
Primary charging
assembly
Positioning knob
Screw
Process unit
Screw
After removal, place each
primary charging assembly
so that its grid side faces up.