5. INSTALLATION
5-24
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
Step
1
2
3
4
Remarks
Work
Turn off the power switch of the copier.
Remove the copier's pick-up assembly
cover. (6 mounting screws)
Remove the copier's rear right cover (3
mounting screws) and the front right
cover (2 mounting screws).
(If the control key is inserted, remove it
in advance.)
Remove the connector cover.
H-1. Installing the Paper Deck for CLC1000
If the paper deck does not come as standard, follow the instructions in the Installation Procedure that
comes with the Paper Deck Installation Kit.
Screws
Screws
Pick-up assembly cover
Screws
Screws
Rear right cover
Front right cover
Connector
cover