background image

 

Page: 4/4 

 

Invisible Reader Installation Instructions 

October 2015 Rev 1.3 

 

Reader Wiring 

 

In Frame or In Door Mounting 

 

1.

 

Use the attached cutout drawing template to make a proper cutout in the door frame or door (as applicable). 

2.

 

Install the mounting tab into the door frame or door (if applicable) 

3.

 

Wire the reader module to the access control panel.  

4.

 

Screw the reader assembly to the mounting tabs or to the door or frame. 

 
 

Troubleshooting 

 

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION 

The reader does not recognize 
a card/tag (no beep, no LED 

flash). 

1.  One or more of the readers’ 
wiring connections are incorrect. 

Power down the reader/access panel and check that 
your wiring is correct. 

 

2.  The reader is not receiving proper 

power from the access panel. 

Measure the voltage at the reader. It should be 

b5 VDC and +14 VDC. 

 

3.  The reader is mounted too close 

to a device that radiates 
electromagnetic interference. 

If possible, install the reader in a different location or 

move any other electronic devices away from the 
reader. 

 

4.  You are using an incorrect type of 

card. 

Make sure you are using an access card that is 

compatible with the reader. 

 

Invisible Reader is compliant with the following organizations: 

 

 

 

 

 

 

 
FCC compliance statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions:   
(1) This device may not cause harmful interference; and  
(2) This device must accept any interference received, including interference that may cause undesired operation. 

Reviews: