CanTech
25
After clicking on the switch, the output switches. Before switching will ask for a name and
password. Login data are stored and the second time to them without asking.
7. Upgrade firmware
Program Ether4_FW.exe used to store the new firmware to Ether4.
IP adresa Ether4 – IP address of card
File – to select the file with the new FW
Send – upgrades the new FW – communication status is printed in window
After the Send command performs the following:
-
Card restarts
-
Introduce a bootloader with the current IP address and MAC address
-
Introduce the new FW
-
The card will reboot and after about 4 seconds starts new program
In carrying out the upgrade should not be broken the connection or power card. If this happens, the
card is broken – it only runs bootloader. When communication is interrupted, procedure may be
performed again. If power is interrupted, bootloader does not use set IP address, but the deafult
(192.168.1.103) and the upgrade must be performed with this IP address.