background image

  

CanTech

 

 

26

8. Connection 

 

 

 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OD 

DC(9-60V) 

OD 

DC(9-60V) 

Relay2 

DC(9-60V) 

NC 

R2 

Relay1 

NO 

NO 

NC 

OD 

Relay1 

NO 

NC 

OD 

 

IN4  IN3  IN2  IN1 

Alarms- 

IN4  IN3  IN2  IN1 

CanTech s.r.o

Poto

č

ní ul. 

č

.p. 2173/40 

787 01 Šumperk 

Tel. 

   

   :   +420 583 250 991, +420 583 250 995 

 
Web     :   www.cantech.cz 
E-mail  :   cantech@cantech.cz 

Example of connecting of external 
relay via OD output 

Error 

Alarm 

Reset 

Operation 

Ethernet 

External 

relay coil 

Thermometers 

OD 

DC+ 

DC- 

Firma CanTech si vyhrazuje právo pro p

ř

ípadné zm

ě

ny. Prosím, kontaktujte obchodního zástupce firmy CanTech pro další informace. 

 

Summary of Contents for Ether 4.1

Page 1: ...on manual CanTech s r o Poto n ul p 2173 40 787 01 umperk Tel 420 583 250 991 E mail cantech cantech cz Web www cantech cz I 64608557 DI CZ64608557 zaps no v OR KS Ostrava odd l C vlo ka 14112 ISO 900...

Page 2: ...10 2 10 Reset the device 10 3 SNMP protocol 11 4 Modbus TCP 11 5 Program for setting Eth4_setting exe 12 5 1 Introduction window and description of menu 12 5 2 HTML setting texts 13 5 3 Config measur...

Page 3: ...unication via Ethernet Communication protocols TCP client server UDP SNMP HTTP XML SMTP Modbus TCP SNTP Updating the firmware via ethernet Internal website to view current status and settings Possibil...

Page 4: ...sing button Reset permanently lights green LED to go out about 7 seconds will be reset to factory settings Note the name is not change only the password and Ethernet settings 2 1 Status display The st...

Page 5: ...ot be set using the HTML It is only possible using program Eth4_nastaven exe As the temperature is measured with a longer period 800ms by default the current measured temperature is displayed in a lig...

Page 6: ...one number can be loaded using the button Load number Measure determines if a value is in a given position measure Trap error fail measurement trap is sent Mail error fail measurements are sending mai...

Page 7: ...ets the minimum value and this is entered at MIN and presses MIN Then set the maximum value and this is entered at Two point and presses Two point At the top left you can see the measured value Note T...

Page 8: ...xt of presence of alarm Text OFF text of cancel the alarm 2 6 Email settings Use mail if they are to be sent emails global ON or OFF Server SMTP server max 29 characters User login for secure servers...

Page 9: ...h site Status in milliseconds If 0 then the refresh does not Switching off Ethernet if checked and fulfilled condition that the first output is controlled by exceeding the limits then when it exceeds...

Page 10: ...measurement fault valarm alarm of limits exceeding measure which values are measured calarm status of the user alarms cmeze limits of user alarms cmod mode for user alarms tidx index of the measured...

Page 11: ...d communicates with Modbus protocol on port 502 The measured values are converted to an integer value according to the number of decimal places and stored in registers starting at address 30001 in 32b...

Page 12: ...en load the settings file Save saves the settings to a file Save as saves the settings to a new file Setting Load loads the entire setting of Ethernet card Save saves entire setting to the Ethernet ca...

Page 13: ...cation over UDP User username for administrator access Read Write community community of SNMP protocol NTP server time server Send mail globally enable of sending mails Enable shutdown ETH see network...

Page 14: ...pulses on the inputs 1 2 Nothing value is not used Measure if the value should be measured Value display of the measurement result after the tap of a button Measure Serial number number of thermomete...

Page 15: ...2 hr 2235 174 This value is roughly every minute saved in EEPROM set minute because memory has a limited number of entries To view the energy is used calculation Value Energy Constant This allows dis...

Page 16: ...d Type Pulse 1 hr 0 1 2 hrs 1 Immediate consumption is calculated as follows Value Constant 40690 104 n Note n may take up maximum 2 32 which corresponding about 29 hours Des m number of decimal place...

Page 17: ...eading thermometers Address MUX address I2C multiplexer Separator character of separator of decimal places Period HTML period of update HTML page Status Input pulse 1 2 delay minimum length SO pulse a...

Page 18: ...opy calculated values are copied into the corresponding fields on the card Values 5 4 Mail mail settings Same as in HTML Format HTML in the mail are used HTML Tags 5 5 Output output settings Used to a...

Page 19: ...t Value1 input value to the thermostat Value2 if selected the difference of Value1 Value2 enters to the thermostat Low1 High1 limits of the thermostat for mod 0 Low2 High2 limits of the thermostat for...

Page 20: ...tput Alarm is evaluated from left to right and parentheses indicate priority As an operand can be used Alarm status of the binary input Value alarm limits of measured values Error measurement error Li...

Page 21: ...CanTech 21 5 7 Discoverer search device in network Finds all Ether4 in network and displays their IP address NB name and MAC address...

Page 22: ...hen repeated detecting state Capture traps if they are to capture incoming traps Read status in trap if the update status of the device when receiving a trap Write Log events stored in the file Ether4...

Page 23: ...unication error IP address device address D if is set the delay of query in menu this field to select the devices that we want to monitor Description description of the device A alarm C user alarm V e...

Page 24: ...Measurement fault For working with data right click menu appears Save data at each reading of state the values are saved into file Export data data is exported to Excel Chart 1 8 values are displayed...

Page 25: ...rinted in window After the Send command performs the following Card restarts Introduce a bootloader with the current IP address and MAC address Introduce the new FW The card will reboot and after abou...

Page 26: ...ech s r o Poto n ul p 2173 40 787 01 umperk Tel 420 583 250 991 420 583 250 995 Web www cantech cz E mail cantech cantech cz Example of connecting of external relay via OD output Error Alarm Reset Ope...