background image

3

Hot

Cold

Alternate Cold Water
Line Fitting Installation

STAT

IM

®

 

AUTOCLAVE

1" MINIMUM

Typical Installation

For 

1

 

Autoclave

1

3

6

7

9

10

4

Drain Line

Sink Drain

S6119 or S6135 

Cold Water Line Fitting

1

2

3

4

9

S7503 

Thermal Regulator Assembly

10

4

5

S6155 

Inline Shut-Off Valve

5

VC250-A 

VistaCheck™ Backflow Preventer

6

TU942 

Coolant Overflow Drain Line

7

8

TU944 

Condensate Drain Line

11

8

12

TU748 

High-Temperature Feed Line

11

12

TU902 

Cold Water Feed Line

S7508 

Inline Thermal Sensor Assembly

S7507 

Drain Line Adapter

2

Summary of Contents for Crosstex VistaCool V7601

Page 1: ...e used with SciCan STATIM 2000 Autoclave SciCan STATIM 5000 Autoclave Includes CSA Certified VistaCheck Dual Check Backflow Preventer PATENT PENDING Direct to Drain Cooling System for Autoclave Wastew...

Page 2: ...ation on SciCan STATIM 2000 and 5000 Autoclave models only S6155 Inline Shut Off Valve S6135 Angle Stop Adapter S7508 Inline Thermal Sensor Assembly VC250 A VistaCheck Dual Check Backflow Preventer S7...

Page 3: ...119 or S6135 Cold Water Line Fitting 1 2 3 4 9 S7503 Thermal Regulator Assembly 10 4 5 S6155 Inline Shut Off Valve 5 VC250 A VistaCheck Backflow Preventer 6 TU942 Coolant Overflow Drain Line 7 8 TU944...

Page 4: ...er 3 to 4 piece of blue poly tubing and connect one end to the outlet end of the inline valve and the other end to the inlet of the supplied CSA certified VistaCheck Dual Check Valve Backflow Prevente...

Page 5: ...ets have been included Simply drill a 7 8 pilot hole through the metal or wood partition then push the smooth plastic grommet into the holes The hole entering the cabinet where the system is installed...

Page 6: ...abinet partition holes If necessary use the high temperature swivel elbow included with the system S1056 to prevent the high temp line connected to the STATIM Autoclave from kinking Connect the black...

Page 7: ...osition Check for blockages in the tubing Autoclave is displaying a cycle fault Exhaust port line is blocked Check for kinks in the tubing from the autoclave to the system manifold Check that water is...

Page 8: ...if the unit is used for purposes other than for what it was designed and manufactured RETURN OF REPLACED COMPONENTS Any item to be replaced under this Warranty must be returned to Crosstex in Phoenix...