background image

canusacps.com

INSTALLATION GUIDE

Option A

Option B

HBE Atomizer 

& Cartridge System

7

Heat the cartridge by means of 
microwave oven, convention oven, 
electrical hot-box etc. to a conditioned 
temperature of 60°C (140°F). 

If using a microwave, a rotating 700 watt 
microwave is recommended. Presuming 
the starting temperature of the cartridge 
is 25°C (77°F), heat the cartridge for 1:00 
minute on both sides of the cartridge for 
a total heating duration of 2:00 minutes. 
Use an infrared temperature gun to 
check the cartridge (in multiple locations 
– top, middle, bottom) to ensure the Base 
side is 50-57°C (122-135°F).

For spraying HBE 3:1 (1000 mL) and Liquid Epoxy Types 4:1 (940 mL)

Install air inlet fi tting to the atomizer gun 
air inlet 1/4” female thread. Attach the 
air supply line to the Atomizer inlet fi t-
ting. The air supply pressure should be 
100 psi (7 bar) and air fl ow rate shall be 
minimum 12 CFM. Only clean and dry air 
should be used.

6

1

2

Canusa Atomizer Gun 

HBE Atomizer Cartridge 3:1 (1000mL)

Atomizer Mixing Tip

Clean exposed steel and adjacent 
pipe coating according to SSPC 
SP 1 to remove the presence of oil, 
grease, and other contaminants. Ensure 
that the pipe is at least 3°C (5°F) above 
the dew point before cleaning. 

Product Description

Surface Preparation

Canusa Atomizer Gun

Liquid Epoxy Type Atomizer Cartridge 4:1 
(940mL)

Atomizer Mixing Tip

Attach Air Supply

Ejector Plate Setup

Atomizer Cartridge Heating

SIS Sa 2½

SSPC SP 10

Thoroughly clean the cutback area 
to “near white metal” SIS Sa 2½ 
(SSPC-SP10) or equivalent. Materials 
used for abrasive blasting shall produce 
an angular surface profi le of 2.5-5 mils 
(64-127 μm) Lightly abrade at least 
50mm (2”) of the line coating on each 
side of cutback area.

3

4

Wipe clean with a lint-free cloth or 
air blast the steel and pipe coating to 
remove foreign contaminants.  Surface 
must be clean and dry prior to applica-
tion of  HBE products.

5

Make sure the correct ejector plate 
is mounted on the top piston of the 
Atomizer Gun. Option A requires the 3:1 
mount plate and Option B requires the 
4:1 mount plate. (Mount plates, screws 
and alan key included with Atomizer 
Gun.)

Reviews: