To obtain the best performance from your fire table, you must perform the following
storage and maintenance activities on a regular basis:
Allow at least 35 minutes for the fire table to cool down after
use, before disconnecting and removing the gas cylinder.
Store the gas cylinder in a dry, well-ventilated and
sheltered area protected from inclement weather and dust,
out of the reach of children, and not in a building, garage or
any other closed area.
The fire table may be stored indoors only if the cylinder is
disconnected and removed.
Keep the fire table area clear and free from combustible
materials, gasoline and other flammable vapours and liquids.
Installation and repair should be done by a qualified service person. The fire table
should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that the control
compartment, burner, and circulating air passageways of the fire table be kept clean.
If you disassemble the burner when cleaning the fire table, please reassemble it
according to the picture on the right to make sure the burner induction tunnel is on
and exactly covers the orifice base. It is imperative that the control compartment,
burner, and circulating air passageways of the fire table be kept clean. It is recommended
not to disassemble the burner.
Permanent installation and repair should be done by a qualified service person. The
fire table should be inspected annually by a qualified service person.
10
STORAGE AND MAINTENANCE
STORAGE AND MAINTENANCE
PROBLEM OBSERV
TROUBLESHOOTING
ED
POSSIBLE CAUSE
CORRECTIVE MEASURES
G as odour
G as leak
See “ If you smell gas ” on page 2.
Check all gas connections.
Delayed ignition
Low gas pressure
Clogged or dirty burner ports
Clogged or dirty burner ports
Blocked orifice
Spent battery
Check gas supply pressure.
Clean burner ports-see manual
section.
Check orifice opening.
Change new battery.
Incorrect burner flame
Incorrect gas supply or
pressure Blocked orifice
Check gas supply pressure.
Check and clean orifice opening.
Clean burner ports.
Summary of Contents for 085-1558-6