background image

Product name

Model No.

Rated Heat Output

Fuel

Gas Supply

Manifold Pressure

Orifice Size (diameter)

Gas Supply Pressure

Blackcomb Outdoor Fire Table 

4

SPECIFICATIONS 

IMPROTANT SAFETY INFORMATION AND PRECAUTIONS 

 

 

Propane—LP

20 lb (9 kg) LP-Gas cylinder

11" W.C.

1.57 mm    

25 PSI (minimum) to 250 PSI (maximum)

   

    The  installation  must  comply  with  local  codes,  or  in  the  absences  of  local  codes  with  the 
National Fuel Gas Code, ANSI Z223.1/NF-PA54;  The  international  Fuel  Gas  Code,  Natural  Gas 
and Propane Installation Code, CSA B149.1; or the Propane Storage and Handling Code, B149.2, 
as applicable. 

   The LP gas supply cylinder to be used must be:
   1-Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)   
     Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for 
     transportation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable;

  2-Provided with a listed overfilling prevention device;
  3-Provided with a cylinder connection device compatible with the connection for the appliance.

     

Always place the appliance on a firm and level surface. 

     

Solid fuels must not be burned in this gas appliance. When using decorative lava rocks, use 

only lava rocks (INCLUDED).

    

The appliance must be used only outdoors in a well-ventilated space and shall not be used in a 

building, garage or any other enclosed area.

   

When  in  use,  keep  the  appliance  area  clear  and  at  least  40" (101.6 cm) side, back and top  

clearance from combustible  materials,  gasoline  and  other  flammable  liquid  and  vapours.  Do 
not  use  the  appliance  under overhead combustible surfaces. Certain items or materials, when 
stored under the appliance or nearby, will be subjected to radiant heat and could be damaged.

     

When in use, keep cylinder area clear and at least 30" (76.2 cm) side clearance from combusti-

ble materials, gasoline and other flammable liquid and vapours. Do not use the appliance under 
overhead combustible surfaces. Certain items or materials, when stored under the appliance or 
nearby, will be subject to radiant heat and could be damaged.

085-1569-0 L-FT1346PST-A

26,000 

BTU/HR  

Summary of Contents for BLACKCOMB 085-1569-0

Page 1: ...xxxxxxx ASSEMBLY INSTRUCTIONS Toll free 1 888 670 6684 IMPORTANT Please read this manual carefully before beginning assembly of this product Keep this manual for future reference 085 1569 0 BLACKCOMB...

Page 2: ...Outdoor Use Only DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame odour property flammable vapours odour 3 Propane tank not included WARNING DANGER BLACKCOMB OUTDOOR...

Page 3: ...nnection Leak test Lighting Storage and maintenance Troubleshooting Limited warranty 3 4 4 6 7 11 12 11 12 13 10 8 10 10 IMPORTANT Please take time to read these instructions thoroughly and follow eac...

Page 4: ...rovided with a cylinder connection device compatible with the connection for the appliance Always place the appliance on a firm and level surface Solid fuels must not be burned in this gas appliance W...

Page 5: ...iance if any part has been under water Immediately call a service technician to inspect the appliance and to replace any part of the control system which has been under water LP Gas supply cylinder to...

Page 6: ...6 EXPANDED VIEW EXPANDED VIEW...

Page 7: ...art Image AA H02015C11 Bolt M6 15 8 1 BB H19001C11 Flat washer M6 8 1 CC H00001C12 Wrench M6 1 0 If you want to replace the parts listed please contact Customer Service Centre 1 888 670 6684 Parts Lis...

Page 8: ...ASSEMBLY 8x 8x 1x 3x 1x...

Page 9: ...ASSEMBLY MODEL N0 1x 1x 1x 085 1569 0 L FT1346PST A...

Page 10: ...ut the cylinder inside 1 Clean the valve and ensure the tank holder is situated in an appropriate location Fig 1 2 Loosen the tank holder retainer bolt by turning counter clockwise Fig 2 Place the pro...

Page 11: ...the leak persists consult Customer Service Centre for assistance at 1 888 670 6684 5 If the connection does not leak continue to the next step 1 Push in and turn control knob to LOW 2 If the burner i...

Page 12: ...e table be kept clean If you disassemble the burner when cleaning the fire table please reassemble it according to the picture on the right to make sure the burner induction tunnel is on and exactly c...

Page 13: ...led or operated according to the instructions or subjected to abuse improperly treated neglected rusted by exposure to the elements misused and or if any repairs maintenance or service has been done b...

Reviews: