IMPROTANT SAFETY INFORMATION AND PRECAUTIONS 

   

The  minimum  distance  between  the  brazier  and  the 

cylinder is 30" (76.2 cm).  
WARNING: The cylinder poses a tripping hazard. 

   Open the door and inspect the hose assembly and burner
prior to each use. If there is evidence of excessive abrasion 
or  wear  or  if  the  hose  or  burner  is  damaged,  it  must  be 
replaced by an appropriate part from the manufacturer. 

   Inspect the gas connections of the appliance prior to each
use. Do not operate the unit if there is a gas leak. Have the 
appliance inspected annually by a qualified service person.  
  The pressure regulator and hose assembly provided with the appliance must be used. The replace-
ment part must be the same as the part specified by manufacturer.
   For instructions on how to connect the LP-Gas tank and check for leaks, please refer to the “Gas 
Connection” on page 9 and “Leak Test” on page 9.

   Children and adults should be alerted to the hazards of high surface temperatures and should stay 
away to avoid burns and prevent clothing ignition. 

   

Young children and pets should be carefully supervised when they are in the area of the appliance.

   

Any guard or other protective device removed for servicing the appliance must be replaced prior 

to operation. 

    

Clothing or other flammable materials should not be hung from the appliance or placed on or near 

the appliance.

   Do not use this appliance if any part has been under water. Immediately call a service technician to 

inspect the appliance and to replace any part of the control system which has been under water. 

    LP-Gas supply cylinder to be used must be constructed and marked in accordance with the specifi-

cations for LP-Gas cylinders of the U.S. Department of Transportation (DOT).

The cylinder supplies system must be arranged for vapour withdrawal and the cylinder must include 

a collar to protect the cylinder valve. 

    Use only 20 lb (9 kg) LP-Gas cylinders.

     

Do not burn wood or any other materials in this appliance.

    

The appliance must be isolated from the gas supply piping system by closing its individual manual 

shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or 
less than 1/2 PSI (3.5 kPa). 

Other cylinders may be acceptable for use with the appliance provided they are compatible with 

the appliance retention means and accompanied by illustration(s) depicting the cylinder mounted on 
the appliance using the cylinder retention means and the point of contact between the cylinder and 
the retention means.

Properly place the hose out of pathways where people may trip over it or 

in areas where they may be subject to accidental damage.

The burner must be replaced prior to the appliance being put into 

operation if it is clear that the burner is damaged. The replacement 
burner must be the same as the part specified by the manufacturer.

To clean the appliance,  including the burner, please refer to “Storage and

Maintenance” on page 1 .

30"

(76.2 cm)

18" (46 cm)

12 1/2" (32 cm) 

Summary of Contents for BLACKCOMB 085-1569-0

Page 1: ...xxxxxxx ASSEMBLY INSTRUCTIONS Toll free 1 888 670 6684 IMPORTANT Please read this manual carefully before beginning assembly of this product Keep this manual for future reference 085 1569 0 BLACKCOMB...

Page 2: ...Outdoor Use Only DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame odour property flammable vapours odour 3 Propane tank not included WARNING DANGER BLACKCOMB OUTDOOR...

Page 3: ...nnection Leak test Lighting Storage and maintenance Troubleshooting Limited warranty 3 4 4 6 7 11 12 11 12 13 10 8 10 10 IMPORTANT Please take time to read these instructions thoroughly and follow eac...

Page 4: ...rovided with a cylinder connection device compatible with the connection for the appliance Always place the appliance on a firm and level surface Solid fuels must not be burned in this gas appliance W...

Page 5: ...iance if any part has been under water Immediately call a service technician to inspect the appliance and to replace any part of the control system which has been under water LP Gas supply cylinder to...

Page 6: ...6 EXPANDED VIEW EXPANDED VIEW...

Page 7: ...art Image AA H02015C11 Bolt M6 15 8 1 BB H19001C11 Flat washer M6 8 1 CC H00001C12 Wrench M6 1 0 If you want to replace the parts listed please contact Customer Service Centre 1 888 670 6684 Parts Lis...

Page 8: ...ASSEMBLY 8x 8x 1x 3x 1x...

Page 9: ...ASSEMBLY MODEL N0 1x 1x 1x 085 1569 0 L FT1346PST A...

Page 10: ...ut the cylinder inside 1 Clean the valve and ensure the tank holder is situated in an appropriate location Fig 1 2 Loosen the tank holder retainer bolt by turning counter clockwise Fig 2 Place the pro...

Page 11: ...the leak persists consult Customer Service Centre for assistance at 1 888 670 6684 5 If the connection does not leak continue to the next step 1 Push in and turn control knob to LOW 2 If the burner i...

Page 12: ...e table be kept clean If you disassemble the burner when cleaning the fire table please reassemble it according to the picture on the right to make sure the burner induction tunnel is on and exactly c...

Page 13: ...led or operated according to the instructions or subjected to abuse improperly treated neglected rusted by exposure to the elements misused and or if any repairs maintenance or service has been done b...