CDE360 Vector Control AC Drive Chapter 6 Parameters Description
Setting
Function
Description
34
Speed control/torque
control switchover
Through the configuration of this function, can realize the switch over
speed control and torque control. Only the vector control support torque
control.
35
Torque control
prohibited
If the configuration of this function is effective, the AC drive force to speed
control.
36
PLC status reset
If the configuration of this function is effective, pause the PLC running
process, resume to the original state, if run again, from the original state.
The PLC related parameter configuration is not be changed.
37
Reverse PID action
direction
The combination of this terminal function and E5.21( PID output
characteristic), can choose PID output characteristic direction. When the
terminal is valid, the output direction is same as E5.21, when the terminal is
invalid, the output direction is opposite to E5.21
38
PID pause
If the configuration of this function is effective, PID stop adjustment, the
output frequency of the AC drive maintains the current state; When the
terminal is invalid, PID resume to adjustment.
39
PID integral pause
If the configuration of this function is effective, the PID integrator stops
accumulating, keep the current constant; When the terminal is invalid, PID
resume to integrator.
40
PID parameter
switchover
When
E5.15
(PID parameter switching conditions) is set to 1(according to
t
he X terminal of switching), through the X terminal’s function configuration,
can switch between the two sets of PID parameters.
When X terminal is invalid, the PID parameter use set one
(
E5.09
~
E5.11
).
When X terminal is valid, the PID parameter use set two(
E5.12
~
E5.14
).
41
PID wakeup
mandatory
PID wake up conditions generally depended by E5.36(wake-up threshold
setting) and
E5.37
(wake-up delay time). PID forced wake up function refers
to whether or not PID wake up conditions are satisfied, as long as X
terminal is valid, PID will exit the dormant state
42
Counter input
Through the configuration of the input count pulse function. When the
frequency is high, you must use the X6/FI. A0.25(pulse count value) do
display the current input count pulse. With the E7.05(set count value) and
E7.06(specified count) and Y terminal function(20: set count arrive, 21:
specify count arrive), you can realize the “Set count reach” and “Specify
count reach” control.
43
Counter reset
Through the configuration of this function, you can clear the current value
A0.25(Pulse count value).