CDE360 Vector Control AC Drive Chapter 6 Parameters Description
H0.25
Range: 0~65535
Default: Factory setting
Product series
number lower
bits
Read only.
H0.26
Range: 0.00~99.99
Default: Factory setting
OTP version
Read only.
Group H1: AI/AO Calibration
These parameters of
H1.00
~
H1.11
are used to calibrate analog inputs, they have been calibrated
upon delivery. Generally, you need not perform calibration in the common applications.
The actual voltage indicates the actual input voltage value measured by instruments such as the
multi-meter.
The display voltage is the drive calculated value which can be monitored from
A0.11
~
A0.13
.
During calibration, send two voltage values to each AI terminal, and save the measured values and
displayed values to the function codes
H1.00~H1.11
, then the AC drive will automatically perform AI
zero offset and gain calibration.
H1.00
~
H1.03
are used to calibrate AI1.
H1.04
~
H1.07
are used to calibrate AI2.
H1.08
~
H1.11
are used to calibrate AI3.
When drive restore factory default value,
H1.00
~
H1.11
will be resumed to factory
calibrated value.
H1.00
Range: 0.500~4.000
Default: Factory setting
AI1 actual
voltage 1
Unit: V
It is used to input the AI1 measured voltage.
H1.01
Range: 0.500~4.000
Default: Factory setting
AI1 display
voltage 1
Unit: V
It is used to input the AI1 display voltage(
A0.11
).
H1.02
Range: 6.000~9.999
Default: Factory setting
AI1 actual
voltage 2
Unit: V
It is used to input the AI2 measured voltage.
H1.03
Range: 6.000~9.999
Default: Factory setting
AI1 display
voltage 2
Unit: V
It is used to input the AI1 display voltage(
A0.12
).
The parameters used to calibrate AI2 and AI3 as below:
Function Code
Name
Function Code
Name
H1.04
AI2 actual voltage 1
H1.08
AI3 actual voltage 1