Troubleshooting
• If any malfunction or abnormal condition is found, immediately stop using machine
and take an appropriate measure according to the Troubleshooting chart below. If
the malfunction or abnormal condition is not listed in the chart, or the suggested
measure does not solve the problem, consult with your CANYCOM representative.
• Some corrective measures listed below require special knowledge and/or
equipment. Please contact your CANYCOM representative in such a case.
Area
Malfunction
Possible Cause
Corrective Measure
Ref.
Oparational
No power supply
even the main
switch is [ON].
(battery gauge is not
indicating)
Faulty connection of
connectors
→Check the connection of
connectors
Faulty connection of
battery connector.
→Check the connection of
battery connector
Battery not charged
sufficiently
→Charge battery
Page 14
Breaker is tripped
→Reset breaker
Page 27
Faulty Switch, Control
Circuit or Wiring
→Please contact your
CANYCOM representative.
Circuit breaker trips
often
Wiring is cut off or short-
circuited
→Turn main switch off
immidiately then please
contact your CANYCOM
representative.
Faulty breaker
→Please contact your
CANYCOM representative.
Others
(other than the above)
→Please contact your
CANYCOM representative.
Battery gauge
flashes
Faulty control circuit or
wiring
→see
Error Messages on
Battery Gauge
Page 25