Capacity of Texas, Inc.
58
027
{4}
Exhaust Gas Recirculation
Valve Position Circuit -
Shorted Low. Low signal
voltage detected at the EGR
Valve Position Sensor Circuit.
Possible low power. EGR
valve will be closed.
0
{3}
Exhaust Gas Recirculation
Valve Delta Pressure Sensor
Circuit - Shorted High. High
signal voltage detected at the
EGR Differential Pressure
Sensor Circuit.
EGR Valve will be closed.
0
{4}
Exhaust Gas Recirculation
Valve Delta Pressure Sensor
Circuit - Shorted Low. Low
signal voltage detected at the
EGR Differential Pressure
Sensor Circuit.
EGR Valve will be closed.
0
{16}
Fuel Inlet Meter Device - Flow
Demand Higher Than
Expected. The ECM has
detected that fuel pressure in
the fuel rail is higher than the
commanded pressure.
Possibility hard to start, lower
power, or engine smoke.
0
{18}
Fuel Inlet Meter Device - Flow
Demand Lower Than
Expected. The ECM has
detected that fuel pressure in
the fuel rail is lower than the
commanded pressure.
None or possible engine noise
(especially at idle or light
load).
633
{31}
Fueling Actuator Number 1
Circuit Error. EFC Actuator
Valve Circuit resistance too
high.
None or possible derate if
pressure control is affected.
190
{31}
Engine Speed Sensor Number
1 - Engine Speed Glitch
Detect. Crankshaft Engine
Speed Sensor Intermittent
Sync.
Possible low power.
723
{31}
Engine Speed Sensor Number
2 - Engine Speed Glitch
Detect. Camshaft Engine
Speed Sensor Intermittent
Sync.
Possible low power.
Table 4-2 CM850 System Fault Codes (Cont.)
Fault
Code
Reason
Effect