Capacity of Texas, Inc.
74
677
{4}
Starter Relay Driver Circuit -
Voltage Below Normal or
Shorted to Low Source. Low
voltage detected at starter
lockout circuit.
The engine will
not
have
starter lockout protection.
167
{16}
Electrical Charging System
Voltage - Data Valid but Above
Normal Operational Range -
Moderately Severe Level.
High battery voltage detected
by the battery voltage monitor
feature.
Amber warning lamp
illuminated until high battery
voltage condition is corrected.
167
{18}
Electrical Charging System
Voltage - Data Valid but Below
Normal Operational Range -
Moderately Severe Level. Low
battery voltage detected by the
battery voltage monitor
feature.
Amber lamp will light until
low battery voltage condition
is corrected.
167
{1}
Electrical Charging System
Voltage - Data Valid but Below
Normal Operational Range -
Most Severe Level. Very low
battery voltage detected by the
battery voltage monitor
feature.
Red lamp illuminated until
very low battery voltage
condition is corrected.
1378
{31}
Engine Oil Change Interval -
Condition Exists. Change
engine oil and filter.
Maintenance reminder
only
.
103
{2}
Turbocharger 1 Speed - Data
Erratic, Intermittent, or
Incorrect. An invalid
turbocharger speed signal has
been detected by the ECM.
None on performance. The
ECM uses an estimated
turbocharger speed.
103
{18}
Turbocharger 1 Speed - Data
Valid but Below Normal
Operational Range -
Moderately Severe Level. Low
turbocharger speed detected by
the ECM.
Engine power derate. The
ECM uses an estimated
turbocharger speed.
Table 4-3 CM2150 System Fault Codes (Cont.)
Fault
Code
Reason
Effect