Trailer Jockey Operators Handbook
87
412
{3}
Exhaust Gas Recirculation
Temperature Sensor Circuit -
Voltage Above Normal or
Shorted to High Source. High
signal voltage detected at EGR
temperature circuit.
EGR valve actuation will be
disabled.
412
{4}
Exhaust Gas Recirculation
Temperature Sensor Circuit -
Voltage Below Normal or
Shorted to Low Source. Low
signal voltage detected at EGR
temperature circuit.
EGR valve actuation will be
disabled.
647
{3}
Fan Control Circuit - Voltage
Above Normal or Shorted to
High Source. Open circuit or
high voltage detected at the fan
control circuit.
The fan may stay on
continuously or
not
run at all.
641
{7}
VGT Actuator Driver Circuit
(Motor) - Mechanical System
Not Responding Properly or
Out of Adjustment. The smart
VGT controller has detected
incorrect stop limits, or the
VGT is unable to move to the
closed position.
VGT travel may be limited.
111
{17}
Coolant Level - Data Valid but
Below Normal Operational
Range - Least Severe Level.
Low engine coolant level
detected.
None on performance.
641
{13}
VGT Actuator Controller - Out
of Calibration. The VGT has
failed the automatic calibration
procedure at initial key-on.
VGT will be in the open
position.
Low intake manifold pressure.
2789
{16}
Turbocharger Turbine Inlet
Temperature (Calculated) -
Data Valid but Above Normal
Operational Range -
Moderately Severe Level.
Turbocharger turbine inlet
temperature has exceeded the
engine protection limit.
Fuel is limited in an attempt to
decrease the calculated exhaust
gas temperature entering the
turbo- charger.
Table 4-3 CM2150 System Fault Codes (Cont.)
Fault
Code
Reason
Effect
Summary of Contents for TJ5000 DOT
Page 2: ......
Page 8: ......
Page 21: ...Trailer Jockey Operators Handbook 13 Figure 2 2 Dash LED Indicators ...
Page 112: ......