6.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R29

. In case the device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 4 - Commands table

).

 

7.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R29

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head  for  the  environment  to  be  monitored.  On  the  way,  to  check  the  quality  of  the  radio  coverage,  use  the  "

Field  Measurer

"  

function. 

This  function  is  activated  issuing  the 

TEST

  (

refer  to 

Picture  4  -  Commands  table

)command:  position  the 

WineCapKey

  in  the  spot 

indicated in 

Picture 3 - WineCapKey positioning

 and wait for two 

AMBER

 flashes, then remove the 

WineCapKey

 from device. The 

"

Field Measurer

" function  lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 seconds cadence.  

For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse 

and activate the "

Field

 

Measurer

" function.

 

 

The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12

 

router

 should be put between (

refer to 

WineCap System - User Manual 

R29

). Th

WR12

 

router

 

itself must be located in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with the 

WR12

 

router

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force 
the operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R29

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

 

 

Picture 6 - Status table - Radio signal quality

 

Summary of Contents for Wine cap WSD10TGII

Page 1: ...ird party external intelligence PLC PC ecc Concerning the MWLI MB 4AO basestation the received information let the basestation to immediately close either relay equipped onboard and physically turn on an external alarm device Please note the datalogger must not be installed upside down with 180 tilt because the result means a discontinuity point and data acquired are wrong the datalogger stores an...

Page 2: ...edure Otherwise in case the device is in FACTORY RESET mode refer to Picture 5 Status table Radio signal quality that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R29 software manual Is necessary to use the WineCapManager software on the PC connected to the basestation that will be coupled with the device b USB Logg...

Page 3: ...etti it 3 9 5 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points Picture 3 Device positioning Picture 4 Wi...

Page 4: ...opped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELES...

Page 5: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 6: ...h count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 9 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 4 Commands table Its corresponds t...

Page 7: ...ght can be extended using WR12 battery powered routers Sealing IP65 Dimensions 90 x 120 x 50mm Weight 550g Case material ABS Mounting 4 points Connections Wireless USB Acceleration Transducer Type Triaxial accelerometer MEMS technology Acceleration Measure Range 16g Acceleration Measure Resolution 100mg Acceleration Alarms Common setup on three axis Inclination Transducer Type Triaxial acceleromet...

Page 8: ...l_R08 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 11 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 9: ... 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The...

Reviews: