background image

 

WSD10TGII 

User Manual

 

 

 

 

 

WA0375E_WSD10TGII_User Manual_R08 

V4.6

 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 
10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 
e-mail info@capetti.it  -  web www.capetti.it

 

 

 

4/9

 

 

The following 

COMMAND

 table describes the available commands:  

Flash count

 

Command

 

Description

 

1 flash 

STATUS 

Shows  the  device  STATUS.  As  answer  the  led  perform  a  flash  sequence  as 
reported in the “STATUS” table. If the device is performing the TEST (

refer to TEST 

command

) this command stops it.  

2 flashes 

TEST 

Enter in TEST mode and transmits status and measurements every 5 seconds. If 
the device is in STANDBY mode or it is out of radio range, this command forces 
the connection procedure to the WSN and the return to the operative mode. The 
TEST  stops  after  120  seconds.  During  TEST  the  led  continuously  shows  the 
STATUS to monitor the received radio signal quality. 

CAUTION: Measures acquired during 

TEST

 phase are NOT saved. 

3 flashes 

ENROLL 

Association  to  the  network:  must  be  used  when  the  device  has  not  yet  been 
included  in  a  network,  starts  the  entry  and  association  procedure  to  the 

basestation

 (

refer to 

WineCap System - User Manual R29

). 

4 flashes 
  
 
+ 4 flashes 

STANDBY 

Temporary device deactivation: the device is stopped. The sampling process and 
the radio are/is turned off losing the connection to the network. To reactivate, a 
TEST  command  is  necessary.  The  STANDBY  command  must  be  given  twice  to 
confirm it: at the first sequence the led flashes alternating RED and GREEN lights, 
waiting  for  the  second  confirm  sequence  within  15  seconds.  At  the  command 
execution the led flashes as the STANDBY status (

refer  to 

WIRELESS MODE STATUS 

Table

). 

5 flashes 
 
 
+ 5 flashes 

FACTORY 

RESET 

The device performs the memory deleting procedure and goes in STOP status. All 
samples,  configuration  and  wireless  network  data  associated  are  LOST.  To 
reactivate the device a new association and configuration procedure is necessary 
(

ENROLL command

). Also in this case, the FACTORY RESET command must be given 

twice  to  confirm  it.  At  the  command  execution  the  led  flashes  as  the 
“PROBE/DATALOGGER  NOT  ASSOCIATED”  status 

refer  to  

WIRELESS  MODE  STATUS 

Table

). 

5 flashes 
 
 
+ 3 flashes 

LOGGER      

NO WSN 

As  the  previous  command  but  performs  only  the  WSN  deleting  procedure  and 
disassociate  from  the 

basestation

.  The  device  enter  in  LOGGER  STAND  ALONE 

mode: data are  kept and the sampling activity CONTINUES  with previous setup. 
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the 
command  execution  wait  for  the  device  reboot.    At  the  STATUS  command, 
“LOGGER” will be the answer (

refer  to  

STAND-ALONE  MODE  STATUS  Table

). A new 

association (

ENROLL command

) is possible to a new 

basestation

 

 

 

Picture 5 - Commands table

 

Summary of Contents for Wine cap WSD10TGII

Page 1: ...ird party external intelligence PLC PC ecc Concerning the MWLI MB 4AO basestation the received information let the basestation to immediately close either relay equipped onboard and physically turn on an external alarm device Please note the datalogger must not be installed upside down with 180 tilt because the result means a discontinuity point and data acquired are wrong the datalogger stores an...

Page 2: ...edure Otherwise in case the device is in FACTORY RESET mode refer to Picture 5 Status table Radio signal quality that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R29 software manual Is necessary to use the WineCapManager software on the PC connected to the basestation that will be coupled with the device b USB Logg...

Page 3: ...etti it 3 9 5 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points Picture 3 Device positioning Picture 4 Wi...

Page 4: ...opped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELES...

Page 5: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 6: ...h count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 9 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 4 Commands table Its corresponds t...

Page 7: ...ght can be extended using WR12 battery powered routers Sealing IP65 Dimensions 90 x 120 x 50mm Weight 550g Case material ABS Mounting 4 points Connections Wireless USB Acceleration Transducer Type Triaxial accelerometer MEMS technology Acceleration Measure Range 16g Acceleration Measure Resolution 100mg Acceleration Alarms Common setup on three axis Inclination Transducer Type Triaxial acceleromet...

Page 8: ...l_R08 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 11 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 9: ... 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The...

Reviews: