WSD10TGII
User Manual
WA0375E_WSD10TGII_User Manual_R08
V4.6
CAPETTI ELETTRONICA s.r.l. - Strada Stratta 57
10090 CASTIGLIONE TORINESE - TORINO - ITALY
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210
e-mail info@capetti.it - web www.capetti.it
4/9
The following
COMMAND
table describes the available commands:
Flash count
Command
Description
1 flash
STATUS
Shows the device STATUS. As answer the led perform a flash sequence as
reported in the “STATUS” table. If the device is performing the TEST (
refer to TEST
command
) this command stops it.
2 flashes
TEST
Enter in TEST mode and transmits status and measurements every 5 seconds. If
the device is in STANDBY mode or it is out of radio range, this command forces
the connection procedure to the WSN and the return to the operative mode. The
TEST stops after 120 seconds. During TEST the led continuously shows the
STATUS to monitor the received radio signal quality.
CAUTION: Measures acquired during
TEST
phase are NOT saved.
3 flashes
ENROLL
Association to the network: must be used when the device has not yet been
included in a network, starts the entry and association procedure to the
basestation
(
refer to “
WineCap System - User Manual R29
).
4 flashes
+ 4 flashes
STANDBY
Temporary device deactivation: the device is stopped. The sampling process and
the radio are/is turned off losing the connection to the network. To reactivate, a
TEST command is necessary. The STANDBY command must be given twice to
confirm it: at the first sequence the led flashes alternating RED and GREEN lights,
waiting for the second confirm sequence within 15 seconds. At the command
execution the led flashes as the STANDBY status (
refer to “
).
5 flashes
+ 5 flashes
FACTORY
RESET
The device performs the memory deleting procedure and goes in STOP status. All
samples, configuration and wireless network data associated are LOST. To
reactivate the device a new association and configuration procedure is necessary
(
ENROLL command
). Also in this case, the FACTORY RESET command must be given
twice to confirm it. At the command execution the led flashes as the
“PROBE/DATALOGGER NOT ASSOCIATED” status
refer to “
).
5 flashes
+ 3 flashes
LOGGER
NO WSN
As the previous command but performs only the WSN deleting procedure and
disassociate from the
basestation
. The device enter in LOGGER STAND ALONE
mode: data are kept and the sampling activity CONTINUES with previous setup.
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the
command execution wait for the device reboot. At the STATUS command,
“LOGGER” will be the answer (
refer to “
). A new
association (
ENROLL command
) is possible to a new
basestation
.
Picture 5 - Commands table