WSD12-THEE 

User Manual

 

 

 

CAPETTI ELETTRONICA s.r.l. - Strada Stratta, 57 
10090 CASTIGLIONE TORINESE - TORINO - ITALY 
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210 
e-mail

 

info@capetti.it

 - web 

www.capetti.it

 

 

WA0154E_WSD12-THEE_User Manual_R03 

V4.8

 

 

1.

 

Description. 

The 

WSD12-THEE

  is  a 

datalogger

  with  2  input  channels  to  acquire  outdoor  temperature  and  relative  humidity,  with  storage 

functionality of samples acquired. 

 

2.

 

Device pre-set and use mode. 

a.

 

Wireless Mode: 

No setup operation is needed. Typically, the system is configured from factory, so the device is already associated to the system 

basestation

. The device is in 

STANDBY

 mode (

refer to

 

Picture 5 - Status table - Radio signal quality

for which is necessary to start it 

with the 

TEST

 command (

refer t

5 - Installation procedure.

). 

Otherwise, in case the device is in 

FACTORY RESET

 mode (

refer to

 

Picture 5 - Status table - Radio signal quality

), that means it's ready 

for  connecting  to  an  existing  system,  in  order  to  associate  it,  make  reference  to  the 

WineCap  System  -  User  Manual  R30

 

software  manual.  Is  necessary  to  use  the  "

WineCapManager

"  software  on  the  PC  connected  to  the 

basestation

  that  will  be 

coupled with the device. 

b.

 

USB Logger Mode: 

For this operation mode, stand-alone 

with data downloads through USB, the connection with the PC and the 

WineCapManager

” 

running on it is necessary in order to modify the device 's operation mode. The sampling interval must be set with the device in 
"

STAND-ALONE

" (

refer t

6 - Stand-alone USB datalogger installation.

mode and automatically, the device 's clock is aligned with the 

PC's clock, in order to assure the temporal reference of the sample. 

Sampling operations start may be selected disconnecting the USB cable or giving the proper command with the magnetic key. 
(

refer  to 

Stand-alone  USB  datalogger  installation.

). More  details on device 's connection/disconnection  through the USB cable are 

available on th

WineCap System - User Manual R30

 

manual. 

c.

 

On field transition from USB to Wireless datalogger: 

This transition is practicable in field, during the sampling period, using the wireless network association command. When the 
association is done, the 

datalogger

 becomes a wireless 

datalogger

 and, besides sending new measures to the 

basestation

, starts 

a download process towards the same 

basestation

 of the measures acquired during the stand-alone period (

refer to

 

Picture 6 - 

Stand-alone datalogger status

).

 

 

Picture 1 - Product Image

 

Summary of Contents for WineCap WSD12-THEE

Page 1: ...ected to the basestation that will be coupled with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 6 Stand alone USB datalogger installation mode and aut...

Page 2: ...al_R03 V4 8 3 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two colors led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points WineCapKey LED Picture 2 Device positioning...

Page 3: ...sary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table 5 flashes 3 flashes LOGGER NO WSN As the previous command but performs only the WSN deleting procedure and disassociate from the basestation The device enters in LOGGER STAND ALON...

Page 4: ... again when the device synchronizes with the WR12 repeater The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run the TEST again refer to WineCap System User Manual R30 NOTE The display equipped datalogger WD04T is recommended to verify the signal quality ...

Page 5: ...acquired 2 input channels Outdoor temperature Relative humidity Sampling interval Selectable from one minute to 24 hours 10 minutes default Datalogger capacity 128 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions...

Page 6: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0154E_WSD12 THEE_User Manual_R03 V4 8 9 Mechanical dimensions Picture 7 Mechanical dimensions ...

Page 7: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Reviews: