7.
Shutting off/Reactivating the device.
If the device is shut off and left unused for a long time, you can issue the
STANDBY
command (
refer to
). It
corresponds to the command number 4 and must be issued twice to confirm the operation.
Picture 3 - WineCapKey positioning
and wait for four
AMBER
flashes, then remove
the
from device.
Verify that the device asks for confirmation of
STANDBY
command with alternate
GREEN/RED
flashing, then position again the
and wait for four flashes again. The device will confirm the
STANDBY
status lighting the
RED
led for 2 seconds twice.
To reactivate the device the
TEST
command must be issued.
8.
Technical Information.
Power supply
8.5Ah -
3.6V type “C” lithium internal battery
Battery life (*)
Up to 5 years
(samples every 10 minutes and radio signal quality at least sufficient)
Measures acquired
(2 input channels)
•
Outdoor temperature
•
Relative humidity
Sampling interval
(
*
)
Selectable from one minute to 24 hours
(10 minutes default)
Datalogger capacity
128,000 samples
(
for each channel
)
Working temperature
•
Operative: -30°C ÷ +60°C
•
Warehousing: -40°C ÷ +70°C
Radio frequency
ISM 868MHz
Radio coverage
Up to 6Km in line of sight
(can be extended using
battery powered repeaters)
Sealing
IP65
Dimensions
•
Datalogger: 90x120x50mm
•
Meteorological protection: 180x95x115mm
Weight
•
Datalogger: 350g
•
Meteorological protection: 330g
Case material
ABS
Mounting
Fix on 4 points
Connections
Wireless, USB
Cable external diameter
4.7mm maximum
Copper wire section
0.05 ÷ 2.5mm² / ÷ 14 AWG
Temperature - Transducer type
PT1000
Temperature - Measure range
-40°C ÷ +80°C
Temperature - Measure accuracy
± 0.1°C at 20°C
(
growing up to ± 0.5°C at full-scale
)
Temperature - Measure resolution
0.01°C
Relative humidity - Transducer type
CMOSens® Technology
Relative humidity - Measure range
0 ÷ 100%
Relative humidity - Measure accuracy
•
±2.5% from 0 to 90%
•
From 90 to 100% change from ±2.5% to ±3.5%
Accuracies are granted between 0°C ÷ 50°C range
Relative humidity - Measure resolution
0.05%RH
* battery life may be influenced by fieldwork conditions, sampling/measuring interval and system configuration
.
** radio coverage reachable using up to 32
(maximum 16 for each path) between the device and the basestation.