3/9

 

 

c.

 

On field transition from USB to Wireless datalogger: 

This transition is practicable in field, during the sampling period, using the wireless network association command. When the 
association  is  done,  the 

datalogger

  becomes  a  wireless 

datalogger

  and,  besides  sending  new  measures  to  the 

basestation

starts  a  download  process  towards  the  same 

basestation

  of  the  measures  acquired  during  the  stand  alone  period  (

refer  to

 

Picture 7 - Stand-alone datalogger status

)

 

4.

 

Wireless device user interface. 

The user interface consists of a “virtual” button that can be activated using th

WineCapKey

 and of a two-coloured led. 

To give a command, user must approach the 

WineCapKey

 to the device’s sensible area and keep it in that position.; the following 

picture (

Picture 4 - WineCapKey positioning

) shows device’s sensible points.  

 

 

 

Picture 3 - Device positioning

 

Picture 4 - WineCapKey positioning

 

WineCapKey 

LED 

Summary of Contents for WineCap WSD12T-IIDR

Page 1: ...1 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 1 9 1 Description The WSD12T IIDR is a datalogger provided with vertical mounting transducers with 3 input channels to acquire inclination an temperature with storage functionality of samples acquired External transducers measures the horizontal axis inclination Picture 1 Product Image Picture 2 Measured axes ...

Page 2: ...function and repeat the reset process WineCapManager software shows and if necessary reset the offset stored in the device using a remote radio command ELECTRONIC LEVEL and RESET READING features are available and works the same for the second tilt channel channel 3 Issue command 7 to use these features on channel 3 the first time for the ELECTRONIC LEVEL twice for RESET READING 3 Device preset an...

Page 3: ...becomes a wireless datalogger and besides sending new measures to the basestation starts a download process towards the same basestation of the measures acquired during the stand alone period refer to Picture 7 Stand alone datalogger status 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a...

Page 4: ...mples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table refer to STAND ALONE MODE STATUS T...

Page 5: ...be located in a position where the signal level is at least sufficient The network will reconfigure itself automatically the signal will be good again when the device synchronizes with the WR12 router The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run ...

Page 6: ...refer to Picture 5 Commands table Its corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the W...

Page 7: ...Datalogger ABS Transducers galvanized iron bracket covered with polybutadiene resin Mounting Datalogger fix on 4 points Transducers fix on 2 points with 4 gross correction Connections Wireless USB 3m cable lenght for each transducer Inclination Transducer type Uniaxial MEMS technology 1 15 Dual Range Automatic Autoscale Inclination Measure range 1 15 Inclination Measure accuracy 0 5 of sample Incl...

Page 8: ...ual_R05 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 10 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 9: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...