4/9

 

 

The following 

COMMAND

 table describes the available commands:  

Flash count

 

Command

 

Description

 

1 flash 

STATUS 

Shows  the  device  STATUS.  As  answer  the  led  perform  a  flash  sequence  as 
reported in the “STATUS” table. If the device is performing the TEST (

refer to TEST 

command

) this command stops it.  

2 flashes 

TEST 

Enter in TEST mode and transmits status and measurements every 5 seconds. If 
the device is in STANDBY mode or it is out of radio range, this command forces 
the connection procedure to the WSN and the return to the operative mode. The 
TEST  stops  after  120  seconds.  During  TEST  the  led  continuously  shows  the 
STATUS to monitor the received radio signal quality. 

CAUTION: Measures acquired during 

TEST

 phase are NOT saved. 

3 flashes 

ENROLL 

Association  to  the  network:  must  be  used  when  the  device  has  not  yet  been 
included  in  a  network,  starts  the  entry  and  association  procedure  to  the 

basestation

 (

refer to 

WineCap System - User Manual R29

). 

4 flashes 
  
 
+ 4 flashes 

STANDBY 

Temporary device deactivation: the device is stopped. The sampling process and 
the radio are/is turned off losing the connection to the network. To reactivate, a 
TEST  command  is  necessary.  The  STANDBY  command  must  be    given  twice  to 
confirm it: at the first sequence the led flashes alternating RED and GREEN lights, 
waiting  for  the  second  confirm  sequence  within  15  seconds.  At  the  command 
execution the led flashes as the STANDBY status (

refer  to 

WIRELESS MODE STATUS 

Table

). (

refer to “

STAND-ALONE MODE STATUS Table

). 

5 flashes 
 
 
+ 5 flashes 

FACTORY 

RESET 

The device performs the memory deleting procedure and goes in STOP status. All 
samples,  configuration  and  wireless  network  data  associated  are  LOST.  To 
reactivate the device a new association and configuration procedure is necessary 
(

ENROLL command

). Also in this case, the FACTORY RESET command must be given 

twice  to  confirm  it.  At  the  command  execution  the  led  flashes  as  the 
“PROBE/DATALOGGER  NOT  ASSOCIATED”  status 

refer  to  

WIRELESS  MODE  STATUS 

Table

). (

refer to “

STAND-ALONE MODE STATUS Table

). 

5 flashes 
 
 
+ 3 flashes 

LOGGER      

NO WSN 

As  the  previous  command  but  performs  only  the  WSN  deleting  procedure  and 
disassociate  from  the 

basestation

.  The  device  enter  in  LOGGER  STAND  ALONE 

mode: data are  kept and the sampling activity CONTINUES with previous setup. 
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the 
command  execution  wait  for  the  device  reboot.    At  the  STATUS  command, 
“LOGGER” will be the answer (

refer  to  

STAND-ALONE  MODE  STATUS  Table

). A new 

association (

ENROLL command

) is possible to a new 

basestation

 

5.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R29

. In case the device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 5 - Commands table

).

 

6.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R29

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head  for  the  environment  to  be  monitored.  On  the  way,  to  check  the  quality  of  the  radio  coverage,  use  the  "

Field  Measurer

"  

function. 

This  function  is  activated  issuing  the 

TEST

  (

refer  to 

Picture  5  -  Commands  table

)command:  position  the 

WineCapKey

  in  the  spot 

indicated in 

Picture 4 - WineCapKey positioning

 and wait for two 

AMBER

 flashes, then remove the 

WineCapKey

 from device. The 

"

Field Measurer

" function  lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 seconds cadence.  

Picture 5 - Commands table

 

Summary of Contents for WineCap WSD12T-IIDR

Page 1: ...1 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 1 9 1 Description The WSD12T IIDR is a datalogger provided with vertical mounting transducers with 3 input channels to acquire inclination an temperature with storage functionality of samples acquired External transducers measures the horizontal axis inclination Picture 1 Product Image Picture 2 Measured axes ...

Page 2: ...function and repeat the reset process WineCapManager software shows and if necessary reset the offset stored in the device using a remote radio command ELECTRONIC LEVEL and RESET READING features are available and works the same for the second tilt channel channel 3 Issue command 7 to use these features on channel 3 the first time for the ELECTRONIC LEVEL twice for RESET READING 3 Device preset an...

Page 3: ...becomes a wireless datalogger and besides sending new measures to the basestation starts a download process towards the same basestation of the measures acquired during the stand alone period refer to Picture 7 Stand alone datalogger status 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a...

Page 4: ...mples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table refer to STAND ALONE MODE STATUS T...

Page 5: ...be located in a position where the signal level is at least sufficient The network will reconfigure itself automatically the signal will be good again when the device synchronizes with the WR12 router The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run ...

Page 6: ...refer to Picture 5 Commands table Its corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the W...

Page 7: ...Datalogger ABS Transducers galvanized iron bracket covered with polybutadiene resin Mounting Datalogger fix on 4 points Transducers fix on 2 points with 4 gross correction Connections Wireless USB 3m cable lenght for each transducer Inclination Transducer type Uniaxial MEMS technology 1 15 Dual Range Automatic Autoscale Inclination Measure range 1 15 Inclination Measure accuracy 0 5 of sample Incl...

Page 8: ...ual_R05 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 10 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 9: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...

Reviews: