background image

WSD10TII 

User Manual

 

 

 

 

 

PAGE   2/11

 

 

WA0425_WSD10TII_User Manual_R02 V6.0 

 

www.

capetti

.it 

1.

 

Disclaimer. 

 

Specifications are subject to change without notice and should not be interpreted as any commitment on the part of Capetti Elettronica 
S.r.l. 

 

Capetti Elettronica S.r.l. assumes no responsibility for any errors that may appear in this document. In no case Capetti Elettronica S.r.l. 
will  be  liable  for  incidental  or  consequential  damages  resulting  from  the  use  of  this  document  or  the  systems  described  in  this 
document. 

 

All Contents published or distributed by Capetti Elettronica S.r.l. are made available for general information purposes. 

 

It is not permitted to publish or use, in whole or in part, such contents for commercial purposes without the explicit written consent 
of Capetti Elettronica S.r.l. 

 

The reproduction, duplication, modification, sale or resale of this material or part of it is not permitted without the explicit written 
consent of Capetti Elettronica S.r.l. 

2.

 

General warnings. 

 

The following information must be read and understood before proceeding with the installation, commissioning and maintenance of 
the devices described in this document. 

 

ATTENTION! Any omission or failure to follow these instructions scrupulously can cause danger. 

 

ATTENTION!  Explosion  hazard.  In  case  of  batteries  substitution,  make  sure  that  the  type  is  compatible  and  complies  with  the 
specifications indicated by the manufacturer. 

 

In case of batteries substitution, DO NOT disconnect the flat cable which connect the electronic boards without removing batteries 
before. 

 

ALWAYS substitute all the batteries, also in case of one single battery exhausted. 

 

If the device is powered by a fixed network, make sure you have disconnected the power supply before carrying out any type of 
intervention. Failure to comply with this indication can cause damage to people and/or property. 

 

Follow the manufacturer's suggested warm-up time (

time required to obtain a reliable measurement

) of the transducer. 

 

Follow the manufacturer's suggested electric wiring of the transducer to measure (

ground shields at a single point, cable length and 

section

); voltage measures on distances exceed 15/20 meters are subjected to electromagnetic disturbances. 0

÷

25mA inputs have a 

superior electromagnetic compatibility (

EMC

). 

 

Avoid passage in cavities with power or high voltage cables. 

 

The protection and safety measures and the warranty provided by the Manufacturer with the equipment may be compromised if it’

used in a manner that does not comply with this user manual. 

 

This equipment complies with CE regulations. 

 

Modifications or tampering not expressly approved by the Manufacturer could void the user's authorization to operate the equipment. 

 

This equipment must be installed by qualified personnel and in accordance with national regulations and/or related local requirements. 

 

Make sure that the object is properly fixed to supports/infrastructures capable of withstanding this load. Make sure proper methods 
and materials are used when fixing the equipment to a wall. 

 

Only service personnel authorized by the manufacturer or personnel expressly authorized by the latter can open the container. There 
are no user serviceable parts inside. 

 

 

Summary of Contents for WSD10TII

Page 1: ...WSD10TII User Manual ...

Page 2: ...ct the electronic boards without removing batteries before ALWAYS substitute all the batteries also in case of one single battery exhausted If the device is powered by a fixed network make sure you have disconnected the power supply before carrying out any type of intervention Failure to comply with this indication can cause damage to people and or property Follow the manufacturer s suggested warm...

Page 3: ...wo thresholds for each inclination channel can be setup two thresholds for CH2 and two thresholds for CH3 Measure sample will be compared with thresholds values with interval obtained by Threshold Following interval value c Value following Step answer Every Threshold Following interval will be compared to the instant value average acquired in a time frame of 8 seconds with the current sample If th...

Page 4: ...nfigurations Device default configurations at the first starting are the following Measure interval 60 minutes Threshold Following interval 5 minutes CH2 and CH3 Follower Enabled with Delta Increase 6 and Delta Decrease 6 Picture 2 Device setup using gateway Picture 3 Channels Axis correspondance ...

Page 5: ...re 5 Command table that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R30 software manual It is necessary to use the WineCapManager software on the PC connected to the gateway that will be linked with the device 8 Wireless device user interface The user interface consists of a virtual button that can be activated usi...

Page 6: ...ess and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to Picture 6 Status table Wireles...

Page 7: ...ponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table FLASH COUNT WIRELESS MODE STATUS RADIO SIGNAL QUALITY 5 green flashes ACTIVE Radio signal Excellent 4 green flashes ACTIVE Radio signal Good 3 green flashes ACTIVE Radio signal Fair 2 amber...

Page 8: ...e issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the WineCapKey and wait for four flashes again The device will confirm the STANDBY status...

Page 9: ...50x60mm Weight 990g Case material ABS Galvanized iron bracket Mounting 4 holes 9mm diameter Gluing using optional bracket FIX WSD10TII Magnetic using FIX MAG WSD10TII with 28Kg total traction force Connections Wireless Inclination Transducer type Three axis accelerometer Inclination Measure range 6 5000 in all the installation positions Automatic zeroing using command issued with WineCapKey Inclin...

Page 10: ...WSD10TII User Manual PAGE 10 11 WA0425_WSD10TII_User Manual_R02 V6 0 www capetti it 13 Mechanical dimensions Picture 7 Mechanical dimensions ...

Page 11: ...the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The end user should contact the device provider ei...

Reviews: