Technical Information
Power supply
19Ah -
3,6V type “D” lithium internal battery
Battery life (*)
Up to 5years
(samples every 60 minutes and radio signal quality at least
sufficient)
Measures acquired
(3 input channels)
•
Temperature
•
Biaxial inclination
Sampling interval
(*)
Selectable from one minute to 24 hours
(60 minutes default)
Datalogger capacity
64,000 samples (
for each channel
)
Working temperature
•
Operative: -
30°C ÷ +60°C
•
Warehousing: -
40°C ÷ +70°C
Radio frequency
ISM 868MHz
Radio coverage
Up to 6Km in line of sight
(can be extended using
Sealing
IP68
Dimensions
150x150x60mm
Weight
990g
Case material
ABS, Galvanized iron bracket
Mounting
•
4 holes - 9mm diameter
•
Gluing using optional bracket
FIX-WSD10TII
•
Magnetic using
FIX-MAG-WSD10TII
with 28Kg total traction
force
Connections
Wireless
Inclination
–
Transducer type
Three-axis accelerometer
Inclination
–
Measure range
+/-
6,5000° in all the installation positions.
Automatic zeroing using command issued with
Inclination
–
Measure resolution
0.0002°
Inclination
–
Repeatability
±0.0005°
Temperature - Transducer type
NTC10KΩ
Temperature - Measure range
-
30°C ÷ +60°C
Temperature
–
Measure accuracy
•
± 0,5°C
Range -
30°C ÷ 0°C
•
± 0,2°C
Range
0°C ÷ +60°C
Temperature - Measure resolution
0.01°C
* battery life may be influenced by fieldwork conditions, sampling/measuring interval and system configuration.
** radio coverage can be extended using up to 32
WR12 repeaters
(maximum 16 for each path) between the device and the gateway.