10.

 

Technical Information. 

Power supply

 

8.5Ah - 

3.6V type “C” lithium internal battery

 

Battery life (*)

 

Up to 5 years  

(samples every  10 minutes and radio signal quality at least sufficient)

 

 

Measures acquired 

(4 input channels)

 

Pulses from clean contact or “open collector”:

 

 

CH1: Thermal Energy 

 

CH2: Volume 

 

CH3/CH4: Heat-transfer fluid temperature 

(Compatibile with any energy meter with pulse digital output)

 

Sampling interval 

(

*

)

 

Selectable from one minute to 24 hours 

(10 minutes default)

 

Datalogger capacity

 

64,000  samples

 

(

for each channel

)

 

Working temperature

 

 

Operative: -30°C ÷ +60°C 

 

Warehousing: -40°C ÷ +70°C  

Radio frequency

 

ISM 868MHz

 

Radio coverage

 

Up to 6Km in line of sight 

(can be extended usin

WR12

 battery powered repeaters)

 

Sealing

 

IP65 

Dimensions

 

90 x 120 x 50 mm 

Weight

 

350g 

Case material

 

ABS 

Mounting

 

Fix on 4 points 

Connections

 

Wireless/USB 

Cable external diameter 

4.7mm maximum 

Copper wire section 

0.05 ÷ 2.5mm² / ÷ 14 AWG 

Thermal energy - Weight counting (

***

)  

Selectable on board: 

CH1 (

KWh

)

 

 

CH1 (

KWh

)

 

1

 

 

1

 

10

 

 

10

 

100

 

 

100

 

1,000

 

 

1,000

 

NTC10K

 BETA 3435 inputs - Transducer type

 

NTC10KΩ

 BETA 3435 (

2 wires

)

 

NTC10K

 BETA 3435 inputs - Measure range

 

-50°C ÷ +105°C

 

NTC10K

 BETA 3435 inputs - Measure accuracy

 

± 0.5°C @ 40°C

 

NTC10K

 BETA 3435 inputs - Measure resolution

 

0.01°C

 

NTC10K

 BETA 3435 inputs - Connection

 

Internal terminal block

 

NTC10K

 BETA 3435 inputs - Sensor input

 

From 0 to 4.5mm Ø cable clamp

 

* battery life may be influenced by fieldwork conditions, sampling interval and system configuration

** radio coverage reachable using up to 3

WR12 repeaters

 (maximum 16 for each path) between the device and the basestation. 

***

 

refer to 

selected transducer’s documentation. Setup DIP switches in proper way.

 

 

 

Summary of Contents for WSD12-EVTT

Page 1: ...regarding the weight expressed in Wh and litres matching the impulse supplied from the energy meter to which the datalogger will be connected Refer to the technical sheet of energy meter To select weights act on the dip switches located in the inner electronic board To verify the correct range setup please refer to the table below NOTE in order that the modification take effect the association bet...

Page 2: ...is operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to assure the te...

Page 3: ...ion procedure to the basestation refer to WineCap System User Manual R30 4 flashes 4 flashes STANDBY Temporary device deactivation the device is stopped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GRE...

Page 4: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 5: ...ashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 8 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 5 Commands table It corresponds to the command number 4 and must be issued twice to confirm the operation Posi...

Page 6: ...M 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions 90 x 120 x 50 mm Weight 350g Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Thermal energy Weight counting Selectable on board CH1 KWh CH1 KWh 1 1 10 10 100 100 1 000 1 000 NT...

Page 7: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0304E_WSD12 EVTT_User Manual_R05 V4 8 11 Mechanical dimensions Picture 9 Mechanical dimensions ...

Page 8: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Reviews: