Wireless device user interface. 

The user interface consists of a “virtual” button that can be activated using th

WineCapKey

 and of a two-colors led. 

To give a command, user must approach the 

WineCapKey

 to the 

device’s sensible

 area and keep it in that position.; the following 

picture (

Picture 3 - WineCapKey positioning

) shows 

device’s sensible

 points.  

 

The following 

COMMAND

 table describes the available commands:  

Flash count

 

Command

 

Description

 

1 flash 

STATUS 

Shows the device STATUS. As answer the led perform a flash sequence as reported 

in the “STATUS” table. 

If the device is performing the TEST (

refer to TEST command

this command stops it.  

2 flashes 

TEST 

Enter in TEST mode and transmits status and measurements every 5 seconds. If 
the device is in STANDBY mode or it is out of radio range, this command forces the 
connection procedure to the WSN and the return to the operative mode. The TEST 
stops after 120 seconds. During TEST, the led continuously shows the STATUS to 
monitor the received radio signal quality. 

CAUTION: Measures acquired during 

TEST

 phase are NOT saved. 

3 flashes 

ENROLL 

Association  to  the  network:  must  be  used  when  the  device  has  not  yet  been 
included  in  a  network,  starts  the  entry  and  association  procedure  to  the 

basestation

 (

refer 

to “

WineCap System - User Manual R30

). 

4 flashes 
  
 
+ 4 flashes 

STANDBY 

Temporary device deactivation: the device is stopped. The sampling process and 
the radio are/is turned off losing the connection to the network. To reactivate, a 
TEST  command  is  necessary.  The  STANDBY  command  must  be  given  twice  to 
confirm it: at the first sequence the led flashes alternating RED and GREEN lights, 
waiting  for  the  second  confirm  sequence  within  15  seconds.  At  the  command 
execution the led flashes as the STANDBY status (

refer to 

WIRELESS MODE STATUS 

Table

). 

5 flashes 
 
 
+ 5 flashes 

FACTORY 

RESET 

The device performs the memory deleting procedure and goes in STOP status. All 
samples,  configuration  and  wireless  network  data  associated  are  LOST.  To 
reactivate the device a new association and configuration procedure is necessary 
(

ENROLL command

). Also in this case, the FACTORY RESET command must be given 

twice  to  confirm  it.  At  the  command  execution  the  led  flashes  as  the 

“PROBE/DATALOGGER  NOT  ASSOCIATED”  status 

refer  to  

WIRELESS  MODE  STATUS 

Table

). 

5 flashes 
 
 
+ 3 flashes 

LOGGER      

NO WSN 

As  the  previous  command  but  performs  only  the  WSN  deleting  procedure  and 
disassociate  from  the 

basestation

.  The  device  enters  in  LOGGER  STAND  ALONE 

mode: data are kept, and the sampling activity CONTINUES with previous setup. 
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the 
command  execution  wait  for  the  device  reboot.    At  the  STATUS  command, 

“LOGGER” will be the answer (

refer to 

STAND-ALONE MODE  STATUS Table

). A new 

association (

ENROLL command

) is possible to a new 

basestation

WineCapKey 

LED 

Picture 4 - WineCapKey positioning

 

Picture 5 - Commands table

 

Summary of Contents for WSD12-EVTT

Page 1: ...regarding the weight expressed in Wh and litres matching the impulse supplied from the energy meter to which the datalogger will be connected Refer to the technical sheet of energy meter To select weights act on the dip switches located in the inner electronic board To verify the correct range setup please refer to the table below NOTE in order that the modification take effect the association bet...

Page 2: ...is operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to assure the te...

Page 3: ...ion procedure to the basestation refer to WineCap System User Manual R30 4 flashes 4 flashes STANDBY Temporary device deactivation the device is stopped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GRE...

Page 4: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 5: ...ashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 8 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 5 Commands table It corresponds to the command number 4 and must be issued twice to confirm the operation Posi...

Page 6: ...M 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions 90 x 120 x 50 mm Weight 350g Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Thermal energy Weight counting Selectable on board CH1 KWh CH1 KWh 1 1 10 10 100 100 1 000 1 000 NT...

Page 7: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0304E_WSD12 EVTT_User Manual_R05 V4 8 11 Mechanical dimensions Picture 9 Mechanical dimensions ...

Page 8: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Reviews: