5.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R30

. In case the 

device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 5 - Commands table

).

 

6.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R30

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head for the environment to be monitored. On the way, to check the quality of the radio coverage, use the "

Field Measurer

" function. 

This function is activated issuing the 

TEST

 (

refer t

Picture 5 - Commands table

)command: position th

WineCapKey

 in the spot indicated 

in 

Picture  3  -  WineCapKey  positioning

  and  wait  for  two 

AMBER

  flashes,  then  remove  the 

WineCapKey

  from  device.  The  "

Field 

Measurer

" function lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 second cadence.  

For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse and 

activate the "

Field

 

Measurer

" function.

 

 

The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long

 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long

 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12 repeater

 should be put between (

refer to 

WineCap System - User Manual 

R30

). Th

WR12 repeater

 

itself must be in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with th

WR12 repeater

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force the 
operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R30

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

 

 

Picture 6 - Status table - Radio signal quality

 

Summary of Contents for WSD12-EVTT

Page 1: ...regarding the weight expressed in Wh and litres matching the impulse supplied from the energy meter to which the datalogger will be connected Refer to the technical sheet of energy meter To select weights act on the dip switches located in the inner electronic board To verify the correct range setup please refer to the table below NOTE in order that the modification take effect the association bet...

Page 2: ...is operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to assure the te...

Page 3: ...ion procedure to the basestation refer to WineCap System User Manual R30 4 flashes 4 flashes STANDBY Temporary device deactivation the device is stopped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GRE...

Page 4: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 5: ...ashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 8 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 5 Commands table It corresponds to the command number 4 and must be issued twice to confirm the operation Posi...

Page 6: ...M 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions 90 x 120 x 50 mm Weight 350g Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Thermal energy Weight counting Selectable on board CH1 KWh CH1 KWh 1 1 10 10 100 100 1 000 1 000 NT...

Page 7: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0304E_WSD12 EVTT_User Manual_R05 V4 8 11 Mechanical dimensions Picture 9 Mechanical dimensions ...

Page 8: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Reviews: