WSD12-LVD
User Manual
CAPETTI ELETTRONICA s.r.l. - Strada Stratta, 57
10090 CASTIGLIONE TORINESE - TORINO - ITALY
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210
e-mail
WA0152E_WSD12-LVD_User Manual_R04
V4.8
The device will give back the radio signal quality through led flashes:
WIRELESS MODE STATUS
Table
Flash count - Wireless mode
Status/Radio signal quality
5 green flashes
Excellent
4 green flashes
Good
3 green flashes
Fair
2 amber flashes
Sufficient
1 red flash
Insufficient
1 red flash 2” long
OUT OF RANGE
Network searching
2 red flashes 2” long
STANDBY
Short-long-short red
flashes series
FACTORY RESET
Device not enrolled
Optimize reception selecting the best position: small movements can help.
If the signal is absent or insufficient at the install point, a
should be put between (
refer to “
itself must be in a position where the signal level is at least sufficient.
The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with the
The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force the
operation. In such cases, put the device in
STANDBY
mode, then run the
TEST
again (
refer to “
WineCap System - User Manual R30
NOTE
: The display equipped
datalogger
) is recommended, to verify the signal quality during devices installation.
7.
Stand-alone USB datalogger installation.
Install the
datalogger
in appropriate place.
If the sampling process has not yet been activated, you can start it through the
Bring it closer to the sensitive point, wait for 2 flashes (
TEST
) (
refer to
) and remove. The
datalogger
begins
sampling according to your settings through your PC.
Through the
is possible to ask for the status, bring it close to the
datalogger
for 1 flash (
STATE
) and remove it.
STAND-ALONE MODE STATUS
Table:
Flash count - Stand-alone mode
STATUS
1 green flash 2 seconds long
ACTIVE
2 red flashes 2 seconds long
STANDBY
Sequence of red flashes: short, 2
seconds long, short
FACTORY RESET
INVALID
datalogger
clock!
PC connection required
Picture 6 - Status table - Radio signal quality
Picture 7 - Stand-alone datalogger status