Contour 5W Series Manual - V4.0
© Capital Fireplaces 2017
14
The minimum distance from the rear of the stove to a wall is 75mm, and 500mm to either side
of the appliance. No combustible material should be within this area (
see below)
.
We recommend at least 1000mm clearance around the stove
(excluding hearths)
, this is
indicated by the Hot Zone in the diagram below. This extends 1000mm from all the windows
and ends where it meets the wall behind the stove. This area can be 90
o
C, so we do not
recommend any combustibles in this area.
Fixing Points
If you would like to fix the stove to the ground, you can do this using the fixing points shown
below. For anchoring the Pedestal model to your hearth you will need x4 M12 bolts and x4
M12 nuts (not supplied).The Log Store model has M12 nuts built into the base, therefore you
will only require x4 M12 bolts (not supplied) for this model.
Log Store Model
Pedestal Model
x4 M12 Nuts
x4 14mm Holes
Views from underneath of the stoves
o
per
ating Instructions
75mm
500mm
500mm
COMBUSTIBLE WALL
HOT ZONE
DOOR
1000m
m
HEARTH
C
L
EAR
A
NCE
T
O
CO
MB
US
TI
BL
E M
A
T
E
RIA
L
300mm
300mm