Curvation & Siesta Series Manual - V2.2
© Capital Fireplaces 2017
16
Log S5
Log S4
Log S3
Log S2
Log S1
Log S6
Log S7
Fircone /
Log S8
Ember Pack
3.5 Fuel Bed Arrangements.
When arranging the Media into the Firebed, it is important that the Pilot area is kept clear and that no
Media enters the Pilot shield. The Pilot area includes the pilot shield and the top of the burner to the first
slot inside the fence of the pilot shield.
When commissioning or servicing the Appliance Cross Lighting must be checked to ensure smooth
lighting of the main burner from the Pilot Flame and smooth lighting of the effect burners from the main
Burner.
Fuel arrangements shown below are for the Double burner, featuring the 2nd Thermocouple. Ensure
that when fitting the fuel beds, the 2nd thermocouple remains clear of the Fuel Bed media, as shown
in the diagrams.
When a single burner is used, arrange the Fuel Bed media in exactly the same arrangement, the only
change will be that the 2nd thermocouple is not present on the single burner.
3.5.1 Firebed Log Lay