background image


 

 

 

 

 

INSTALLATION AND OPERATING 

INSTRUCTIONS 

 

 

 

APPROVED - CONFORMING TO EN13240:2001 and 

EN13240 A2:2004 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 

 

APPLICABLE TO THE FOLLOWING STOVE MODELS: 

VEGA EDGE 200SL (ECO) 

AVEBURY (ECO) 

BASSINGTON (ECO) 

SCENE (ECO) 

SIGMA (ECO) 

 

STOVES MUST BE FITTED BY APPROVED, QUALIFIED AND  

COMPETENT INSTALLERS 

 

PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER 

Stoves operate at very high temperatures.  All persons  

including children and the infirm should be warned of this and not  

allowed to touch any surfaces whilst in use.  The operator must use  

the glove provided. 

 

 

   SL ECO SERIES INSTRUCTION – REV.C – NOV 2018 

These appliances have been approved by HETAS Ltd as an intermittent operating appliance for 
burning wood and approved smokeless fuels at the nominal output of 5.0kW only.

 

 

Summary of Contents for AVEBURY

Page 1: ...LLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Stoves operate at very high temperatures All persons including children and the infirm should be warned of this and not allowed to touch any surfac...

Page 2: ...2 AVEBURY ECO SCENE ECO BASSINGTON ECO STANDARD LEGS BASSINGTON ECO SKIRTED LEGS BASSINGTON ECO BASELINE LEGS SIGMA ECO VEGA EDGE 200SL ECO...

Page 3: ...DIMENSIONS OUTPUT EFFICIENCY PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 11 GENERAL MAINTENANCE PAGE 17 SAFETY NOTES TROUBLESHOOTING PAGE 19 STOVE ACCESSORIES PAGE 22 COMPONENT PARTS PAGE 23 TECHNICA...

Page 4: ...m 615mm 80mm 317mm 114mm 324mm 364mm 443mm 575mm 530mm SCENE ECO 485mm 635mm 95mm 327mm 114mm 324mm 352mm 456mm 595mm 504mm SIGMA ECO 500mm 645mm 105mm 313mm 114mm 322mm 369mm 468mm 605mm 536mm VEGA E...

Page 5: ...SUPPLIERS ACCEPT NO RESPONSIBILITY IF THIS ADVICE IS NOT FOLLOWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS...

Page 6: ...an 230mm If this cannot be met then an appropriate liner should be fitted by a suitably approved method A 125mm flue liner may be used in accordance with the Building Regulations The chimney and conne...

Page 7: ...on remove the baffle plates bricks and door Place in a secure place to avoid damage Refit after installation Upon completion of installation the appliance should be checked under fire for soundness of...

Page 8: ...fully set the stove upright and check that all internal components are correctly positioned Clearances If the stoves are to be installed adjacent to materials that can catch fire like wood then the fo...

Page 9: ...l the stove and secure the hearth If existing floors do not have adequate load bearing capacity then suitable modifications must be adopted When the stove is in the desired position fix the brackets p...

Page 10: ...ing with a flue draft stabiliser into houses built before 2008 at least 1500mm 2 additional means of permanent ventilation direct to outside is required Houses built after this date will require addit...

Page 11: ...11 OPERATION SLIDING PRIMARY AIR CONTROL TYPE ROTARY PRIMARY AIR CONTROL TYPE Secondary Air Control Riddling Mechanism Primary Air Control Secondary Air Control Riddling Mechanism Primary Air Control...

Page 12: ...hracite fires It should be closed when a wood fire is established for the best efficiency Secondary Air Secondary air is controlled via the sliding vent above the door it is this airwash that keeps a...

Page 13: ...low the fuel to reach a steady glow and build up the fire gradually Once you have a good fire established across the fire bed further fuel can be added as required When your fire is well established y...

Page 14: ...e and prevent efficient burning Solid fuel produces ash which if allowed to build up will stifle the air flow through the grate and eventually cause the fire to die Caution only empty the ash pan when...

Page 15: ...Approval does not cover the use of other fuels either alone or mixed with the recommended fuels listed above nor does it cover instructions for the use of other fuels Wood Only kiln dried or well sea...

Page 16: ...r Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any...

Page 17: ...g can cause excess smoke Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in th...

Page 18: ...avoid accidental damage Inner Grate Removal and Replacement Remove the ash pan and detach the riddling arm from the underside of the circular inner grate Lift the inner grate vertically and manoeuvre...

Page 19: ...ppliance should be cleaned again and the chimney swept it is essential to have the chimney swept at least once annually and it is recommended that it is swept twice a year Safety Notes and Troubleshoo...

Page 20: ...eject and safely dispose of fuel from the appliance 3 Check for a flue blockage and clean if required Do not attempt to relight the fire until the cause has been identified and corrected If necessary...

Page 21: ...fuels vary in heat value check with your coal merchant as to suitability Dirty Glass Nearly always caused by poor fuel quality check the moisture content of the wood you are burning with a moisture me...

Page 22: ...e to supply Matching graphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Stove Fan Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Pur...

Page 23: ...p panel FFVE4003 18 Stove bottom panel FFVE3002 5 Secondary air control plate FFVE2023 19 Ash Pan FFVE2014 6 Flue collar FFVE008CE 20 Primary air slide plate FFVE2020 7 Baffle plate FFVE3007 21 Stove...

Page 24: ...23 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029...

Page 25: ...3 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8...

Page 26: ...3 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8...

Page 27: ...egs FFVE7010 4 Stove top panel FFVE7003 17 Outer grate FFVE3005 5 Secondary air control plate FFVE7023 18 Stove bottom panel FFVE7002 6 Flue collar FFVE008CE 19 Ash Pan FFVE2014 7 Baffle plate FFVE300...

Page 28: ...FFVE3007 16 2 x bottom fire brick FFVE4042 4 Stove top panel FFVE7003 17 Ash Pan FFVE2014 5 Rear fire brick FFVE2013 18 Glass panel FFVE4018 6 Stove rear panel FFVE3034 19 Stove tool FFVE029 7 Flue bl...

Page 29: ...econdary air control plate WW FFVE2023BSC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8 Heat shield FFVE2032...

Page 30: ...DEMARK PERCY DOUGHTY CFL 2 MODEL IDENTIFIER BASSINGTON ECO 3 ENERGY CLASS A 4 DIRECT HEAT OUTPUT 5 0kW 5 INDIRECT HEAT OUTPUT N A 6 ENERGY EFFICIENCY INDEX 112 0 7 ENERGY EFFICIENCY AT NOMINAL HEAT OU...

Page 31: ...EFFICIENCY INDEX 112 0 7 ENERGY EFFICIENCY AT NOMINAL HEAT OUTPUT 84 0 8 SPECIFIC PRECAUTIONS SEE MANUAL 1 SUPPLIER NAME OR TRADEMARK PERCY DOUGHTY CFL 2 MODEL IDENTIFIER VEGA EDGE 200SL ECO 3 ENERGY...

Page 32: ...el 01204 868 550 Fax 01204 868 551 Email sales percydoughty com Website www penmancollection co uk For South of England Sales please contact Capital Fireplaces Ltd Unit 12 17 Henlow Trading Estate Hen...

Reviews: