PERFORMANCE

Verena Eco / Vega Verena Eco Solid Fuel Stove Manual Version 1.4 Issued

 

18.06.21

This document is to be left with the householder after installation.

All our stoves exceed the safety and performance requirements of European Standards.
Independently tested by SGS (Notified Laboratory No: 0608) in 2018.
Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.

Fuel

Wood (Beech)

Test Standard

EN13240

Test Cycle

1.03kg over 0.73hrs

Settings

Top Valve 50%

Flue Draft Pa (ins WG)

12 (0.05)

Efficiency %

75.4

Recommended Rating kW

4.9

Mean Flue Gas Temp Rise ° K

283

Minimum air entry requirement

2500mm

2

Minimum clearance to combustibles

Rear – back of chamber must be non-combustible. 
Sides – 600mm

Weight

52Kg

Flue outlet size

125mm

Emissions as if O2 = 13%

Nox mg/m

3

111

CO %

0.10

CxHy mg/m

2

73

Gas Flow g/sec

4.8

Smoke emission mg/m

3

30

Read these instructions!  Use only recommended fuels!

1

SUPPLIER NAME OR TRADEMARK

2

MODEL IDENTIFIER

VERENA ECO / VEGA VERENA ECO 

3

ENERGY CLASS RATING

A

4

DIRECT HEAT OUTPUT

4.9KW

5

INDIRECT HEAT OUTPUT

N/A

6

ENERGY EFFICIENCY INDEX

99

7

ENERGY EFFICIENCY AT NOMINAL HEAT OUTPUT

75.4%

8

SPECIFIC PRECAUTIONS

SEE MANUAL

Summary of Contents for VEGA VERENA ECO

Page 1: ...V E R E N A E C O S T O V E I N S T R U C T I O N S PLEASE READ THESE INSTRUCTIONS AND USE ONLY THE RECOMMENDED FUELS ...

Page 2: ...STOVE CLEARANCES FLUE LINER YOUR FIREPLACE AIR SUPPLY EXTRACTOR FANS FITTING LIVING WITH YOUR STOVE 8 9 10 12 OPERATING TOOLS LIGHTING FILLING DAMPERS CONTROL EMPTYING ASHES EXTENDED BURNING CO ALARM AEROSOLS CLEAN WINDOWS DOOR SUMMER SHUT DOWN SMOKE CONTROL WOOD SPARE PARTS TROUBLESHOOTING MAINTENANCE 12 13 14 15 15 REDUCING CARBON EMISSIONS IN THE UK ...

Page 3: ...a small amount of fuel QUICK START GUIDE To get the most out of your stove you should take the time to read the instructions provided This guide is intended to help you get the best possible fire started Even if you have previous experience with stoves all makes and models vary and the information below will help you gain the optimum performance from your new stove Open the door and use a poker to...

Page 4: ...Top Valve 50 Flue Draft Pa ins WG 12 0 05 Efficiency 75 4 Recommended Rating kW 4 9 Mean Flue Gas Temp Rise K 283 Minimum air entry requirement 2500mm2 Minimum clearance to combustibles Rear back of chamber must be non combustible Sides 600mm Weight 52Kg Flue outlet size 125mm Emissions as if O2 13 Nox mg m3 111 CO 0 10 CxHy mg m2 73 Gas Flow g sec 4 8 Smoke emission mg m3 30 Read these instructio...

Page 5: ...the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The Verena Eco and Vega Verena Eco stoves may be used in smoke control areas strictly in accordance with these instruc...

Page 6: ...ury Weight Your stove is heavy take great care when moving it and ensure that the intended fireplace can support the weight consider fitting a load distributing plate Fireguard Safety A fireguard must be used in the presence of children and old and or infirm people The fireguard should be manufactured in accordance with BS 8423 2002 Fireguards for use with solid fuel appliances Your Chimney Once w...

Page 7: ... of any doubt fit a purpose made air vent An extractor fan or another fuel using appliance in the same building can remove this air Fit a Carbon Monoxide alarm near to the stove Regarding installations in rooms with extractor fans For solid fuel appliances avoid installing extract ventilation in the same room If mechanical extraction is unavoidable then seek specialist advice to ensure the install...

Page 8: ...ility before the appliance is installed Remedial action should be taken if required seeking expert advice if necessary Where the chimney is believed to have previously served an open fire installation it is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is therefore recommend...

Page 9: ...use of at least 12Pa and not in excess of 25 Pa Verena Eco Base 1 Lift the Verena stove onto the top of the base and ensure that it is correctly aligned Please note that the stove is a heavy appliance and two people should lift it carefully 2 Remove all vermiculite insulation bricks from the base of the stove 3 Place two washers onto the two bolts supplied and drop the bolts through the two holes ...

Page 10: ... that is needed Don t fill above the level shown in the diagram below Dampers left open Operation with the appliance dampers or air controls left open can cause excess smoke The appliance must not be operated with air controls appliance dampers or door left open except as directed in these instructions Control How fast the fire burns depends on how much air reaches the fuel The stove has an air co...

Page 11: ...n the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note on page 15 Air Supply It is essential that the fire has adequate air supply for combustion and ventilation Apertures provided for this purpose shall not be restricted Aerosol Sprays Do not use an aerosol spray near the appliance under fire Keeping the window clean Simply operating the...

Page 12: ...or your stove Part Number Description 1 Door Glass 2 Door without glass 3 Log Retention Bar Mk2 ST CONT45F LOG RETAINER 1 x2 Mk2 ST CONT45F LOG RETAINER CURVED 4 Lower Base Vermiculite pair POD FIRE BASE VERMICULITE 5 Right Side Vermiculite VERENA POD 2018 RH SIDE VERMICULITE 6 Base Vermiculite 450 PS 404 7 Upper Back Vermiculite 450 PS 402 8 Lower Back Vermiculite 450 PS 403 9 Left Side Vermiculi...

Page 13: ...IGHT LIMITS UNLESS OTHER STATED MILLIMETERS ANGULAR TOLERANCE 0 15 TOLERANCES MUST NOT BE CUMULATIVE DRAWING SIZE A3 MATERIAL DRAWN JK DATE CHECKED DATE DEBURR ALL SHARP EDGES ISSUE NUMBER This drawing and any information or descriptive material set out on it are the confidential and copyright property of Aerotool Ltd and MUST NOT BE DISCLOSED COPIED LOANED in whole or part or used for any purpose...

Page 14: ...s set control to the lowest practical setting A chimney thermometer from your local stove shop can help Smoke Coming Into Room Fumes are poisonous smoke emission must never be tolerated causes might be New stove There is often a smell and sometimes visible fumes as the paint cures This normally stops after an hour or so and we advise that you open a window when firing up a new stove for the first ...

Page 15: ...nd corrected If necessary seek expert advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean at all times Maintenance Monthly Check that the flue is clear and unblocked and that the door seals are sound Annually Sweep the chimney the entire length of the chimney from stove to outlet should be swept New Parts Your stove has been ext...

Page 16: ...Tel 01462 813138 Fax 0800 980 4847 Email sales capitalfireplaces co uk Website www capitalfireplaces co uk For North of England sales please contact Percy Doughty Co Ltd Imperial Point Express Trading Estate Stone Hill Road Farnworth BL4 9TN Tel 01204 868550 Fax 01204 868551 Email sales percydoughty com Website www percydoughty com ...