27
Installation advice
INSTALLATION
4
4
IMPORTANT
✓
The appliance should be installed, regulated and adapted to
function with other types of gas by a QUALIFIED INSTAL-
LATION TECHNICIAN.
Failure to comply with this condition will render the guaran-
tee invalid.
✓
The appliance must be installed in compliance with regula-
tions in force.
✓
Installation technicians must comply to current laws in force
concerning ventilation and the evacuation of exhaust gases.
✓
Always unplug the appliance before carrying out any main-
tenance operations or repairs.
✓
The appliance must be housed in heat-resistant units.
✓
These tops are designed to be embedded into kitchen
fixtures measuring 600 mm in depth.
✓
The walls of the units must not be higher than work top
and must be capable of resisting temperatures of 105
°C above room temperature.
✓
Do not instal the appliance near inflammable materials
(eg. curtains).
TECHNICAL INFORMA-
TION FOR THE INSTALLER
In order to install the cooker top into
the kitchen fixture, a hole with the
dimensions shown in fig. 4.1 (for cook-
er top P90) o 4.2 (for cooker top P60)
has to be made, bearing in mind the
following:
✓
within the fixture, between the
bottom side of the cooker top and
the upper surface of any other
appliance or internal shelf there
must be a clearance of at least 30
mm;
✓
the cooker top must be kept no less
than 200 mm away from any side
wall (figs. 4.1 - 4.2).
✓
the hob must be installed at least
60 mm from the wall.
✓
there must be a distance of at least
650 mm between the hob and any
wall cupboard or extractor hood
positioned immediately above (see
figs. 4.3-4.4).
✓
It is absolutely essential that you
place a separator between the base
of the hob and the drawer unit.
✓
if the hob is installed over a built-in
oven, there must be a distance of at
least 30 mm between the two appli-
ances. The two appliances should
be connected to the gas supply with
independent connections.
860
480
500
60 min
0
– 2
840
200 min
0
– 2
Fig. 4.1
580
480
500
60
0
–2
560
200
0
–2
Fig. 4.2