ELECTRICAL CONNECTION
•
The installation of this appliance and the connection to the electrical network should only
be carried out by a qualified electrician.
•
When installing, make sure no part of the hob is under stress or tension.
•
Necessary Connection data is placed on the hob casing near the connection box.
•
Connection to the mains must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3mm.
•
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Always connect the Earth Wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver.
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the bridge between terminal 1 and 2,
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L1 to the
terminal 1 and the Phase L2 to the terminal 2.
Caution!
Frequent loosening and screwing of the screws on the connection box risks
damaging the efficiency of the tightness once screwed. It is therefore
advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
Mains
Connection
Cable diameter
Cable
Protection
calibre
230V~ 50/60Hz
1 Phase + N
5 x 1,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
5 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.